Related Experiment Video
Updated: Jun 20, 2026

Analysis of Organochlorine Pesticides in a Soil Sample by a Modified QuEChERS Approach Using Ammonium Formate
Published on: January 20, 2023
Miniaturized matrix solid phase dispersion procedure and solid phase microextraction for the analysis of
Y Moliner-Martinez1, P Campíns-Falcó, C Molins-Legua
1Department of Analytical Chemistry, Faculty of Chemistry, University of Valencia, C/Dr Moliner, 50, 46100 Burjassot, Valencia, Spain.
Abstract:
This work has developed a miniaturized method based on matrix solid phase dispersion (MSPD) using C18 as dispersant and acetonitrile-water as eluting solvent for the analysis of legislated organochlorinated pesticides (OCPs) and polybrominated diphenylethers (PBDEs) in biota samples by GC with electron capture (GC-ECD). The method has compared Florisil-acidic Silica and C18 as dispersant for samples as well as different solvents. Recovery studies showed that the combination of C18-Florisil was better when using low amount of samples (0.1 g) and with low volumes of acetonitrile-water (2.6 mL). The use of SPME for extracting the analytes from the solvent mixture before the injection resulted in detection limits between 0.3 and 7.0 microg kg(-1) (expressed as wet mass). The miniaturized procedure was easier, faster, less time consuming than the conventional procedure and reduces the amounts of sample, dispersant and solvent volume by approximately 10 times. The proposed procedure was applied to analyse several biota samples from different parts of the Comunidad Valenciana.
More Related Videos
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Types of Detectors