Pulse Wave Velocity Testing in the Baltimore Longitudinal Study of Aging
Published on: February 7, 2014
Validation and reproducibility of aortic pulse wave velocity as assessed with velocity-encoded MRI
Heynric B Grotenhuis1, Jos J M Westenberg, Paul Steendijk
1Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands.
Purpose:
To validate magnetic resonance imaging (MRI) assessment of aortic pulse wave velocity (PWV(MRI)) with PWV determined from invasive intra-aortic pressure measurements (PWV(INV)) and to test the reproducibility of the measurement by MRI.
Materials And Methods:
PWV(MRI) was compared with PWV(INV) in 18 nonconsecutive patients scheduled for catheterization for suspected coronary artery disease. Reproducibility of PWV(MRI) was tested in 10 healthy volunteers who underwent repeated measurement of PWV(MRI) at a single occasion. Velocity-encoded MRI was performed on all participants to assess PWV(MRI) in the total aorta (Ao(total)), the proximal aorta (Ao(prox)), and the distal aorta (Ao(dist)).
Results:
The results are expressed as mean +/- SD, Pearson correlation coefficient (PCC), and intraclass correlation (ICC). Good agreement between PWV(MRI) and PWV(INV) was found for Ao(total) (6.5 +/- 1.1 m/s vs. 6.1 +/- 0.8 m/s; PCC = 0.53), Ao(prox) (6.5 +/- 1.3 m/s vs. 6.2 +/- 1.1 m/s; PCC = 0.69), and for Ao(dist) (6.9 +/- 1.1 m/s vs. 6.1 +/- 1.0 m/s; PCC = 0.71). Reproducibility of PWV(MRI) was high for Ao(total) (4.3 +/- 0.5 m/s vs. 4.6 +/- 0.7 m/s; ICC = 0.90, P < 0.01), Ao(prox) (4.3 +/- 0.9 m/s vs. 4.7 +/- 1.0 m/s; ICC = 0.87, P < 0.01), and Ao(dist) (4.3 +/- 0.6 m/s vs. 4.4 +/- 0.8 m/s; ICC = 0.92, P < 0.01).
Conclusion:
MRI assessment of aortic pulse wave velocity shows good agreement with invasive pressure measurements and can be determined with high reproducibility.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Imaging Studies for Cardiovascular System IV: CMRI
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of blood pressure in brachial artery(two-step method)
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for: