Ballistocardiogaphic studies with acceleration and electromechanical film sensors
1Tampere University of Technology, Department of Biomedical Engineering, Tampere, Finland. jarmo.alametsa@tut.fi
Abstract:
The purpose of this research is to demonstrate and compare the utilization of electromechanical film (EMFi) and two acceleration sensors, ADXL202 and MXA2500U, for ballistocardiographic (BCG) and pulse transit time (PTT) studies. We have constructed a mobile physiological measurement station including amplifiers and a data collection system to record the previously mentioned signals and an electrocardiogram signal. Various versions of the measuring systems used in BCG studies in the past are also presented and evaluated. We have showed the ability of the EMFi sensor to define the elastic properties of the cardiovascular system and to ensure the functionality of the proposed instrumentation in different physiological loading conditions, before and after exercise and sauna bath. The EMFi sensor provided a BCG signal of good quality in the study of the human heart and function of the cardiovascular system with different measurement configurations. EMFi BCG measurements provided accurate and repeatable results for the different components of the heart cycle. In multiple-channel EMFi measurements, the carotid and limb pulse signals acquired were detailed and distinctive, allowing accurate PTT measurements. Changes in blood pressure were clearly observed and easily determined with EMFi sensor strips in pulse wave velocity (PWV) measurements. In conclusion, the configuration of the constructed device provided reliable measurements of the electrocardiogram, BCG, heart sound, and carotid and ankle pulse wave signals. Attached EMFi sensor strips on the neck and limbs yield completely new applications of the EMFi sensors aside from the conventional seat and supine recordings. Higher sensitivity, ease of utilization, and minimum discomfort of the EMFi sensor compared with acceleration sensors strengthen the status of the EMFi sensor for accurate and reliable BCG and PWV measurements, providing novel evaluation of the elastic properties of the cardiovascular system.
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Dysrhythmias V: Evaluating Dysrhythmias
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...