Related Experiment Video
Updated: Jun 20, 2026

Determination of the Excitation and Coupling Rates Between Light Emitters and Surface Plasmon Polaritons
Published on: July 21, 2018
Plasmon-Coupled Fluorescence Probes: Effect of Emission Wavelength on Fluorophore-Labeled Silver Particles
Jian Zhang1, Yi Fu, Mustafa H Chowdhury
1Center for Fluorescence Spectroscopy, University of Maryland School of Medicine, Department of Biochemistry and Molecular Biology, 725 West Lombard Street, Baltimore, Maryland 21201.
Abstract:
We examined the emission intensity and wavelength of 40 nm diameter silver particles covalently coated with organic fluorophores with different absorption and emission wavelengths. The objective of this study is to use the interactions of fluorophores with the plasmon in the metal particles to create the brightest possible probes. We refer to the complexes as plasmon-coupled fluorescence probes (PCPs). The fluorophores were separated from the metal cores by 10 nm long polymer backbones. The fluorescence was observed to be enhanced for seven fluorophores with emission wavelength from 450 to 700 nm. The enhancement efficiency was shown to approximately increase with long wavelengths for the silver particle-bound fluorophores. When comparing a single fluorophore free in solution and bound to the silver particle, the emission intensity increases 3- to 17-fold. The relationship between the enhancement efficiency and loading number of fluorophore on each silver particle was studied to optimize the conditions for PCP brightness. Compared with the free single fluorophores in the absence of metal, the optimized single labeled silver particles were even more than 1000-fold brighter, showing their potentials in the applications of sensitive clinical and biological assays.
More Related Videos
14:12Dual-Color Fluorescence Cross-Correlation Spectroscopy to Study Protein-Protein Interaction and Protein Dynamics in Live Cells
Published on: December 11, 2021
07:15Measuring Interactions between Fluorescent Probes and Lignin in Plant Sections by sFLIM Based on Native Autofluorescence
Published on: January 2, 2020
Related Concept Videos
Labeling DNA Probes
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
Protein Dynamics in Living Cells
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...
Fluorescence and Phosphorescence: Instrumentation
Super-resolution Fluorescence Microscopy
Variables Affecting Phosphorescence and Fluorescence
Photoluminescence: Applications