Related Experiment Video
Updated: Jun 20, 2026

Single-throughput Complementary High-resolution Analytical Techniques for Characterizing Complex Natural Organic Matter Mixtures
Published on: January 7, 2019
Revolving hollow fiber-liquid phase microextraction coupled to GC/MS using electron ionization for quantification of
1Department of Chemistry, National Sun Yat-Sen University, Kaohsiung, Taiwan.
Abstract:
A dynamic liquid phase microextraction method using a revolving hollow fiber was demonstrated for coupling to GC/MS [using EI (electronic ionization) and selected ion monitor (SIM)] as a concentrating probe for rapid analysis and quantitative determination of five aromatic hydrocarbon isomers (cumene; propylbenzene; 2-ethyltoluene; 1,2,3-trimethylbenzene; and 1,2,4-trimethylbenzene) from biological matrices (human urine and human plasma). This technique was named as revolving hollow fiber-liquid phase microextraction (RHF-LPME). The optimized parameters of RHF-LPME coupled to GC/MS experiments were extraction solvent, toluene; extraction time, 2 min; sample agitation rate, 700 rpm; salt concentration, 0%; rotating speed for motor driving rotator, 250 rpm; and the rotator was operated in a reversed direction with the stirrer. The linear range of calibration curve of RHF-LPME was from 0.002 to 0.4 microg/mL with R(2) > 0.9916 and the RSD values were from 4.5 to 5.2%. Additionally, comparing to single drop microextraction (SDME), this method offers better limits of detection (LODs) and EF (enrichment factor). This approach exhibits many advantages including simplicity, rapid detection with high reproducibility and high extraction efficiency, easy to operate and fast to reach equilibrium for analyzing biological samples. This approach has the potential to be widely used because it only requires simple devices to perform all extraction processes. We believe that this technique can be a powerful tool for GC/MS analysis of biological samples and clinical applications in the near future.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Performance Liquid Chromatography: Elution Process
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Mass Spectrometry: Aromatic Compound Fragmentation