Background:
Atrioventricular (AV) node vagal stimulation (AVNVS) has recently emerged as a novel approach to controlling AV dromotropic function. Animal studies have demonstrated that selective epicardial AVNVS is effective in controlling ventricular rate (VR) acutely and in the long term. Endocardial AVNVS has been shown to significantly reduce VR acutely during atrial fibrillation (AF) in humans. However, no data are available on its long-term reproducibility.
Objectives:
The purpose of this study was to demonstrate that the posteroseptal right atrium is a suitable site for permanent pacing and allows AVNVS in humans both acutely and during follow-up.
Methods:
In 12 candidates for implantable cardioverter-defibrillator with a history of AF, the atrial lead was implanted in the posteroseptal right atrium, where advanced AV block was achieved during temporary high-frequency stimulation (HFS). On implantation and 3-month follow-up examination, HFS was delivered through the permanent lead to demonstrate the possibility to gradually slow the VR until complete AV block.
Results:
On implantation, VR during AF was gradually slowed until complete AV block, which was elicited at 4.3 V (0.2 ms, 50 Hz). After 3 months, this effect remained reproducible. No significant change in pacing thresholds was observed after 3 months. We observed one dislodgment and one microdislodgement of atrial leads.
Conclusions:
Our study demonstrates, for the first time in humans, that selective placement of the atrial lead yields electrical characteristics suitable for permanent pacing and enables VR to be significantly reduced under HFS. These results, which were reproducible during follow-up, provide data for the development of device-based control of VR during AF.
More Related Videos
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
16:40A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
Related Concept Videos
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...
Electrophysiology of Normal Cardiac Rhythm
Mechanism of Cardiac Arrhythmias