Simultaneous observation of rotational coherent Stokes Raman scattering and coherent anti-Stokes Raman scattering in

Optics Letters
|September 1, 2009
PubMed

Related Concept Videos

Raman Spectroscopy: Overview01:20

Raman Spectroscopy: Overview

The underlying principle of Raman spectroscopy is based on the interaction between light and matter, specifically molecules' inelastic scattering of photons. When a monochromatic beam of light, typically from a laser source, interacts with a sample, most scattered light has the same frequency as the incident light. This is known as Rayleigh scattering.
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
Raman Spectroscopy Instrumentation: Overview01:26

Raman Spectroscopy Instrumentation: Overview

A conventional Raman spectrophotometer includes a laser source, a sample holding system, a wavelength selector, and a detector.
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Stokes' Law01:20

Stokes' Law

Viscous forces, like friction, are intermolecular forces that resist the relative motion of molecules over each other. When a solid body moves through a liquid, viscous forces drag it in the opposite direction. The force's magnitude depends on the solid's shape and size, as well as its speed and the liquid's coefficient of viscosity, density and temperature.
The expression for the force on a solid spherical object in a fluid is called Stokes' law. Stokes' law is valid only for low Reynolds...
Atomic Absorption Spectroscopy: Interference01:25

Atomic Absorption Spectroscopy: Interference

Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
2D NMR: Homonuclear Correlation Spectroscopy (COSY)01:06

2D NMR: Homonuclear Correlation Spectroscopy (COSY)

Homonuclear correlation spectroscopy, or COSY, is a 2-dimensional NMR technique that provides information about coupled protons. Typically, the geminal and vicinal coupling are observed. For example, consider the COSY spectrum of ethyl acetate, where its 1D proton NMR spectrum is plotted along the vertical and horizontal axes with their corresponding chemical shift scale. Three spots on the diagonal corresponding to the three peaks in the 1D proton spectrum are called diagonal peaks. The COSY...
Atomic Absorption Spectroscopy: Instrumentation01:22

Atomic Absorption Spectroscopy: Instrumentation

An atomic absorption spectrophotometer (AAS) comprises several components: a radiation source, an atomizer, a monochromator, and a detector. The radiation source can be a hollow-cathode lamp (HCL) or an electrodeless-discharge lamp (EDL), both of which provide a narrow emission line of the required wavelength. However, some instruments use continuum sources and high-resolution monochromators to achieve a narrow range of radiation.
The atomizer used in AAS can be either a flame atomizer or an...