Related Experiment Video
Updated: Jun 20, 2026

Facile Preparation of Ultrafine Aluminum Hydroxide Particles with or without Mesoporous MCM-41 in Ambient Environments
Published on: May 11, 2017
Which aluminium fractionation method will give true inorganic monomeric Al results in fresh waters (not including
1Dept of Applied Environmental Science (ITM), Stockholm University, SE-106 91 Stockholm, Sweden. cecilia.andren@itm.su.se
Abstract:
Aluminium solubility and toxicity increase with acidification. There is no standardized analytical method for the determination of inorganic monomeric Al (Al(im)), which is the form that causes toxicity to fish. Separation by cation exchange is commonly combined with other analytical methods, such as complexation with pyrochatechol violet (PCV) or 8-hydroxyquinoline (HQ) and total quantification using graphite furnace or inductively-coupled plasma emission. Data from 14 laboratories were obtained for a dilution series of Al(im) samples; the results of the Al(im) analysis were statistically evaluated. The Al(im) levels were altered through pH, which was controlled by the addition of calcium hydroxide. Confounding parameters such as total organic carbon (TOC) or fluoride (F) were controlled. The total determination and HQ methods yielded significantly higher Al(im) concentrations than the PCV method. Pretreatment by passage through a 0.45 microm filter and pH-adjustment of the ion exchange column had no apparent effect on the Al(im) yield. However, ultra filtration (<10 kDa) caused a significant reduction in the Al(im) concentration using the HQ method. The ultra filtrated Al(im) fraction was similar to the PCV results in the interlaboratory comparison. Retention of colloidal bound Al in the cation exchange column may result in overestimation of Al(im) when the total and HQ methods are used. Estimated Al(im) concentrations derived from two equilibrium models were similar to PCV-derived Al(im) concentrations, as well as the HQ method using ultra filtrated water. The fact that the PCV method does not detect colloidal Al, neither before nor after ion exchange, makes this a preferred technique for Al(im) analysis. Because of the variability in the reported Al(im) concentrations that can arise when different analytical procedures are used, the adoption of a single, reliable technique will facilitate inter-study comparisons and provide consistency in the detection of trends in environmental monitoring programs.
Related Concept Videos
Coagulation
Qualitative Analysis
For instance, group IV...
Precipitation and Co-precipitation
Classifying Matter by Composition
According to its composition, the matter can be classified into two broad categories — pure substances and mixtures.
A pure substance is a form of matter that has a constant composition throughout with uniform properties. For example, any sample of sucrose has the same composition and same physical properties, such as melting point, color, and sweetness, regardless of the source from which it is isolated.
A mixture is composed of two or more types of...
Washing, Drying, and Ignition of Precipitates
Gravimetry: Inorganic And Organic Precipitating Agents
