Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Examination of intercostal arteries with transthoracic Doppler sonography
Tetsuya Koyanagi1, Nobuyoshi Kawaharada, Yoshihiko Kurimoto
1Sapporo Medical University, Department of Thoracic and Cardiovascular Surgery, Department of Traumatology and Critical Care Medicine, Chuo-ku, Sapporo, Japan. koyanagitetsuya@hotmail.co.jp
Objective:
There has been no study on the measurement of blood flow of the intercostal artery (ICA) or lumbar artery (LA) with the use of transthoracic Doppler sonography. Here, the method of the ICA depiction and flow measurement were described, and we suggested the clinical usage of this method.
Methods:
Twelve healthy subjects were examined. The performance of transthoracic Doppler sonography was approached from the back on lateral decubitus position. The intercostal artery was depicted by two-dimension mode with color flow, and the inner diameter was measured. Peak systolic velocity (PSV), end-diastolic velocity (EDV), velocity-time integral (VTI), and heart rate (HR) were measured with pulsed Doppler, and the blood flow was calculated.
Results:
Bilateral ICAs and LAs from Th4 to L4 were measurable with this method. The PSV of Lt Th9 was the fastest at 43.3 +/- 10.1 cm/sec and the PSV of the ICAs gradually decreased as distance from Th9 increased. As for the flow volume, the left Th11 was the greatest at 99.7 mL/min, and the flow volume of the ICA gradually decreased as distance from Th11 increased. The velocity and blood flow of right ICA tended to be lower than the left in the same spinal level.
Conclusions:
Evaluation technique of serial ICAs and LAs was shown. We think that it may be a clinically useful method in the study of spinal cord circulation in the repair of cases of descending thoracic or thoracoabdominal aortic aneurysm.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...