Related Experiment Video
Updated: Jun 20, 2026

Removal of Trace Elements by Cupric Oxide Nanoparticles from Uranium In Situ Recovery Bleed Water and Its Effect on Cell Viability
Published on: June 21, 2015
Persistence and decontamination of surrogate radioisotopes in a model drinking water distribution system
Jeffrey G Szabo1, Christopher A Impellitteri, Shekar Govindaswamy
1United States Environmental Protection Agency, National Homeland Security Research Center, Water Infrastructure Protection Division (MS NG-16), Cincinnati, OH 45268, USA. szabo.jeff@epa.gov
Abstract:
Contamination of a model drinking water system with surrogate radioisotopes was examined with respect to persistence on and decontamination of infrastructure surfaces. Cesium and cobalt chloride salts were used as surrogates for cesium-137 and cobalt-60. Studies were conducted in biofilm annular reactors containing heavily corroded iron surfaces formed under shear and constantly submerged in drinking water. Cesium was not detected on the corroded iron surface after equilibration with 10 and 100mgL(-1) solutions of cesium chloride, but cobalt was detected on corroded iron coupons at both initial concentrations. The amount of adhered cobalt decreased over the next six weeks, but was still present when monitoring stopped. X-ray absorption near-edge spectroscopy (XANES) showed that adhered cobalt was in the III oxidation state. The adsorbed cobalt was strongly resistant to decontamination by various physicochemical methods. Simulated flushing, use of free chlorine and dilute ammonia were found to be ineffective whereas use of aggressive methods like 14.5M ammonia and 0.36M sulfuric acid removed 37 and 92% of the sorbed cobalt, respectively.