Fetal Doppler mechanical PR interval: correlation with fetal heart rate, gestational age and fetal sex
A Wojakowski1, G Izbizky, M E Carcano
1Fetal Medicine Unit, Hospital Italiano de Buenos Aires, Buenos Aires, Argentina.
Objectives:
To establish normal fetal values for the mechanical PR interval by pulsed-wave Doppler at 16-36 weeks of gestation, and to evaluate the influence of fetal heart rate (FHR), gestational age (GA) and fetal sex.
Methods:
Fetal mechanical PR intervals were evaluated prospectively by obstetric ultrasound examination. Healthy mothers with sonographically normal fetuses from singleton pregnancies were included. Mechanical PR intervals were measured from simultaneous mitral and aortic Doppler waveforms, from the onset of left atrial contraction (mitral A-wave) to the onset of left ventricular ejection (aortic pulse wave). Simple and multiple linear regression analyses were performed to examine the correlation between PR interval and GA, FHR and fetal sex.
Results:
We evaluated 336 fetuses at 16-36 weeks. The mean +/- SD FHR was 143.4 +/- 8.3 beats per min (bpm). The PR intervals had a typical Gaussian distribution with a mean +/- SD of 122.4 +/- 10.3 ms. Robust linear regression showed that the PR increased by about 0.40 ms (95% CI, 0.22-0.58) per gestational week (P < 0.001), and this relationship remained after adjustment for FHR and fetal sex. PR intervals diminished by 1.4 (95% CI, 0.75 to 2.0) ms for each 5 bpm increase in FHR (P < 0.001), independently of GA and fetal sex. No fetal sex differences were observed.
Conclusions:
We provide normal fetal values for the mechanical PR interval at 16-36 weeks of gestation. Mechanical PR intervals in normal fetuses are influenced by GA and FHR independently, and both variables should be taken into account when evaluating fetuses at risk for congenital heart block.
Related Concept Videos
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...