Related Experiment Video
Updated: Jun 20, 2026

Brain Infarct Segmentation and Registration on MRI or CT for Lesion-symptom Mapping
Published on: September 25, 2019
Z-score mapping method for extracting hypoattenuation areas of hyperacute stroke in unenhanced CT
Noriyuki Takahashi1, Du-Yih Tsai, Yongbum Lee
1Department of Radiological Technology, Graduate School of Health Sciences, Niigata University, Chuou-ku, Niigata, 951-8518, Japan. b07b401b@mail.cc.niigata-u.ac.jp
Rationale And Objectives:
The purpose of this study was to develop a z-score mapping method on the basis of a voxel-by-voxel analysis to visualize hypoattenuation areas of hyperacute stroke on unenhanced computed tomographic (CT) images.
Materials And Methods:
The algorithm of the developed method consisted of five main steps: anatomic standardization, the construction of a normal reference database, calculation of the z scores, the elimination of false-positive areas, and the extraction of hypoattenuation areas. The obtained z-score map was then superimposed on the original CT images for identifying hypoattenuation areas of hyperacute stroke on the unenhanced CT images. The method was applied to 21 patients with infarctions of the middle cerebral artery territory <3 hours after symptom onset. The performance of the method was evaluated using receiver-operating characteristic analysis.
Results:
Hypoattenuation regions could be significantly distinguished from normal regions by z-score values (P < .0001). The area under the receiver-operating characteristic curve for distinction between 68 hypoattenuation regions and 142 normal regions was 0.834.
Conclusions:
The developed method has the potential to accurately indicate high-signal intensity areas corresponding to hypoattenuation areas on CT images in the hyperacute stage of stroke.
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT