Related Experiment Video
Updated: Jun 20, 2026

Standardized Hemorrhagic Shock Induction Guided by Cerebral Oximetry and Extended Hemodynamic Monitoring in Pigs
Published on: May 21, 2019
Central venous oxygen saturation for the diagnosis of low cardiac output in septic shock patients
1Department of Intensive Care, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark. anders.perner@rh.regionh.dk
Background:
Simple diagnostic tests are needed to screen septic patients for low cardiac output because intervention is recommended in these patients. We assessed the diagnostic value of central venous oxygen saturation in the superior vena cava (ScvO(2)) for detecting low cardiac output in patients with septic shock.
Methods:
We conducted a prospective observational study in three general intensive care units (ICUs) of adult patients with septic shock, who were to have a catheter inserted for thermodilution measurement of cardiac index (CI(TD)). Paired measurements of CI(TD) and central venous oximetry values were obtained when the clinician first measured CI(TD).
Results:
We included 56 patients with septic shock and a mean sequential organ failure assessment score of 12 (range 3-20). Baseline CI(TD) was 3.5 l/min/m(2) (1.0-6.2) and ScvO(2) of 70% (33-87). The best cut-off of ScvO(2) for CI(TD)>2.5 l/min/m(2) (n=42) was a value >or=64% with positive and negative predictive values of 91% (95% confidence interval 79-98) and 91% (59-100), respectively. The diagnostic values were not improved by using instead central venous O(2) tension or the difference between arterial and central venous O(2) saturation.
Conclusions:
This prospective, observational study found that a ScvO(2) measurement of >or=64% indicated CI(TD)>2.5 l/min/m(2) in ICU patients with septic shock.
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send blood...
