Assessment of mitochondrial potential: implications for the correct monitoring of human sperm function

A Amaral1, J Ramalho-Santos

  • 1Department of Zoology, Center for Neuroscience and Cell Biology, University of Coimbra, Coimbra, Portugal.

Insights

This study evaluated fluorescent probes for assessing sperm mitochondrial membrane potential (MMP). JC-1 showed the most promise for dynamic MMP monitoring, though fixative compatibility remains a challenge.

Area of Science:

  • Reproductive Biology
  • Cellular Biology
  • Biochemistry

Background:

  • Mitochondrial membrane potential (MMP) is crucial for sperm functionality.
  • Assessing MMP dynamically requires reliable fluorescent probes.
  • Distinct probes' performance in dynamic MMP evaluation is not well-established.

Purpose of the Study:

  • To determine the dynamic evaluation capabilities of MitoTracker Green, MitoTracker Red, and JC-1 for sperm MMP.
  • To assess the impact of MMP disruptors and fixatives on these probes.
  • To identify the most suitable probe for sperm MMP assessment.

Main Methods:

  • Human sperm samples were labeled with MitoTracker Green, MitoTracker Red, and JC-1.
  • Probes' ability to monitor MMP was tested using disruptors (KCN, FCCP, valinomycin).
  • The effect of fixatives (formaldehyde, methanol) on probe performance was evaluated.

Main Results:

  • All three probes monitored MMP changes induced by disruptors.
  • JC-1 partially reflected MMP alterations post-labeling.
  • Probes stained pre-fixed sperm variably; none were reliably fixable.

Conclusions:

  • JC-1 appears most adequate for sperm MMP assessment, but probe choice depends on experimental goals.
  • Careful selection of probes and appropriate controls are essential for accurate MMP evaluation.
  • Fixation methods significantly impact the reliability of MMP assessment using these probes.