Pulse pressure and QRS width evaluation as an inexpensive tool for heart failure assessment
Luís Beck-da-Silva1, Lívia Goldraich, Laísa Bonzanini
1Hospital de Clínicas de Porto Alegre, Federal University of Rio Grande do Sul, Porto Alegre-RS, Brazil. lbneto@hcpa.ufrgs.br
Abstract:
Decreased pulse pressure (PP) is associated with low cardiac output and increased mortality in heart failure (HF) inpatients. QRS width is a well-known prognostic factor in HF. The study purpose was to explore the mortality effect of combining PP and QRS width in HF outpatients. Initial sphygmomanometrically determined PP and QRS width on the first electrocardiograph in 327 consecutive patients at an HF clinic were recorded. According to PP > or = or <40 mm Hg and QRS width > or = or <120 ms, patients were classified into 4 groups. Study groups were analyzed for their effect on mortality using Cox proportional hazards regression analysis. Patients with PP <40 mm Hg had higher mortality (59% vs 45%; P=.015). QRS width > or =120 ms indicated a trend toward higher mortality (57% vs 48%; P=.067). Actuarial survival curves showed that group 4 (QRS width > or =120 ms and PP <40 mm Hg) had significant increased mortality risk in 3.5 years' mean follow-up. Group 4 had a mean survival time of 1124 days (SD=124) vs 2233 days (SD=285) in group 1 (QRS width <120 ms and PP > or =40 mm Hg) (P=.022). There was a linear association between left ventricular ejection fraction (LVEF) and study groups. PP and QRS width are readily available, inexpensive, and relevant clinical measures to help identify HF outpatients with significantly worse prognosis and decreased LVEF.
Related Concept Videos
Pulse
The pulse serves as a clinical indicator...
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring pulse