Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Matrix-Assisted Laser Desorption Ionization (MALDI)01:08

Matrix-Assisted Laser Desorption Ionization (MALDI)

Matrix-assisted laser desorption ionization (MALDI) is a powerful analytical technique used in mass spectrometry. It enables the identification and characterization of various biomolecules, including proteins, peptides, nucleic acids, and carbohydrates. MALDI is an ionization technique, widely employed in biological and medical research, as well as in fields like pharmacology and biochemistry.The analyte of interest, a biomolecule or a mixture of biomolecules, is mixed with a suitable matrix...
Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation01:26

Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation

Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy  (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview01:19

Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview

In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then passed on to...
High-Performance Liquid Chromatography: Types of Detectors01:15

High-Performance Liquid Chromatography: Types of Detectors

The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte properties and...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle01:19

Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle

Inductively coupled plasma (ICP) is the most widely used plasma source in atomic emission spectroscopy (AES), also known as Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). The ICP source, or torch, consists of three concentric quartz tubes with argon gas flowing through them. A spark from a Tesla coil initiates the ionization of argon, generating a high-temperature plasma.
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Quantitative evaluation and visualization of lumbar foraminal nerve root entrapment by using diffusion tensor imaging: preliminary results.

AJNR. American journal of neuroradiology·2011
Same author

[Thoracic aortic aneurysm due to giant cell arteritis without any specific symptom].

Kyobu geka. The Japanese journal of thoracic surgery·2009
Same author

[Gigantic coronary aneurysm arisen from coronary fistula between the left circumflex artery and the left ventricle].

Kyobu geka. The Japanese journal of thoracic surgery·2008
Same author

Direct refolding of recombinant human growth differentiation factor 5 for large-scale production process.

Journal of bioscience and bioengineering·2005
Same author

[A case of sepsis by Neisseria meningitidis beginning with pneumonia during a trip abroad].

Kansenshogaku zasshi. The Journal of the Japanese Association for Infectious Diseases·2001
Same author

[A case of fluorouracil-induced pneumonitis].

Nihon Kyobu Shikkan Gakkai zasshi·1998

Related Experiment Video

Updated: Jun 20, 2026

Automated Delivery of Microfabricated Targets for Intense Laser Irradiation Experiments
06:40

Automated Delivery of Microfabricated Targets for Intense Laser Irradiation Experiments

Published on: January 28, 2021

Sensitive photon detector based on selective laser ionization.

T Okada, H Andou, Y Moriyama

    Optics Letters
    |September 16, 2009
    PubMed
    Summary
    This summary is machine-generated.

    A novel selective laser ionization photodetector (SLIP) utilizes atomic gas for detection, offering high quantum efficiency within a narrow bandwidth. This innovative approach replaces traditional photoelectric surfaces, paving the way for enhanced photodetector technology.

    More Related Videos

    Laser-Induced Fluorescence Emission (L.I.F.E.) as Novel Non-Invasive Tool for In-Situ Measurements of Biomarkers in Cryospheric Habitats
    13:38

    Laser-Induced Fluorescence Emission (L.I.F.E.) as Novel Non-Invasive Tool for In-Situ Measurements of Biomarkers in Cryospheric Habitats

    Published on: October 26, 2019

    Direct Imaging of Laser-driven Ultrafast Molecular Rotation
    10:52

    Direct Imaging of Laser-driven Ultrafast Molecular Rotation

    Published on: February 4, 2017

    Related Experiment Videos

    Last Updated: Jun 20, 2026

    Automated Delivery of Microfabricated Targets for Intense Laser Irradiation Experiments
    06:40

    Automated Delivery of Microfabricated Targets for Intense Laser Irradiation Experiments

    Published on: January 28, 2021

    Laser-Induced Fluorescence Emission (L.I.F.E.) as Novel Non-Invasive Tool for In-Situ Measurements of Biomarkers in Cryospheric Habitats
    13:38

    Laser-Induced Fluorescence Emission (L.I.F.E.) as Novel Non-Invasive Tool for In-Situ Measurements of Biomarkers in Cryospheric Habitats

    Published on: October 26, 2019

    Direct Imaging of Laser-driven Ultrafast Molecular Rotation
    10:52

    Direct Imaging of Laser-driven Ultrafast Molecular Rotation

    Published on: February 4, 2017

    Area of Science:

    • Atomic Physics
    • Photonics
    • Optical Detectors

    Background:

    • Photomultiplier tubes (PMTs) traditionally use photoelectric surfaces for light detection.
    • Existing photodetectors may have limitations in quantum efficiency and detection bandwidth.

    Purpose of the Study:

    • To propose and demonstrate a novel selective laser ionization photodetector (SLIP).
    • To explore the potential of atomic gas as a detection medium for enhanced photodetector performance.

    Main Methods:

    • Utilizing an atomic-gas target as the core detection element.
    • Employing resonant absorption of signal radiation by the atomic gas.
    • Selective photoionization of the excited atomic gas using an intense laser beam.

    Main Results:

    • Demonstration of the selective laser ionization photodetector (SLIP) concept.
    • Analysis indicates potential for high quantum efficiency.
    • Potential for operation within a limited detection bandwidth.

    Conclusions:

    • The SLIP offers a promising alternative to conventional photodetectors.
    • Atomic gas detection enables selective and efficient light signal capture.
    • Initial experiments validate the SLIP's feasibility and performance potential.