Related Experiment Video
Updated: Jun 20, 2026

Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Effect of Thermo-mechanical Load Cycling on Microleakage in Class II Ormocer Restorations
Dina Erdilek1, Can Dörter, Fatma Koray
1Dr, Department of Operative Dentistry, Faculty of Dentistry, Istanbul University, Istanbul, Turkey.
Objectives:
The objective of this in vitro study was to evaluate the marginal sealing ability of an ormocer in comparison with a hybrid composite when using thermocycling and load cycling procedures together in the study design.
Methods:
Modified proximal Class II cavities were prepared on the mesial and distal surfaces of twenty-two human premolars. Each tooth was restored with Admira and contralaterally with TPH Spectrum. Half of all of the teeth were subjected to thermo-mechanical load cycling. After dye penetration, longitudinal sections in mesio-distal direction were prepared and examined under a stereomicroscope. Data were analyzed with Mann Whitney U test.
Results:
The results showed that the thermo-mechanical load cycling caused a statistically significant increase in gingival microleakage when compared with the non-thermocycled and non-loaded restorations for both the materials Admira (P=0.006) and TPH Spectrum (P=0.023).
Conclusions:
Simultaneous load cycling and thermocycling are decisive factors in the in vitro assessment of gingival microleakage, which still remains to be a clinical problem even with the ormocer system Admira.