Impact of scattering and spherical aberration in contrast sensitivity
Guillermo M Pérez1, Silvestre Manzanera, Pablo Artal
1Laboratorio de Optica, Departamento de Física, Universidad de Murcia, Campus de Espinardo, Edificio CiOyN, Murcia, Spain. gperez@um.es
Abstract:
We investigated the impact in spatial visual performance of the combined presence of different amounts of spherical aberration and intraocular scattering in the eye. In a group of subjects, contrast sensitivity at 6 cycles per degree was measured when viewing through holographic diffusers to produce different levels of scattering and with their spherical aberration simultaneously controlled using an adaptive-optics visual simulator. For elevated levels of scattering, the addition of small amounts of spherical aberration either does not decrease, or even may slightly increase, contrast sensitivity under some conditions. This seems to be due to an optical effect also demonstrated in an artificial eye. Although the visual effect is quite small, this finding could suggest a balancing mechanism where larger spherical aberration could keep relatively stable the retinal image quality under the presence of elevated scattering. This is actually the situation in older eyes with both spherical aberration and intraocular scatter being higher than in young eyes.
More Related Videos
06:55Scanning Light Scattering Profiler (SLPS) Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses
Published on: June 6, 2017
06:46Investigating the Deployment of Visual Attention Before Accurate and Averaging Saccades via Eye Tracking and Assessment of Visual Sensitivity
Published on: March 18, 2019
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Focusing of Light in the Eye
Anatomy of the Eyeball