Related Experiment Video
Updated: Jun 20, 2026

Modified Octopus Technique for Thoracoabdominal Aortic Aneurysm
Published on: August 1, 2025
Contemporary treatment of patients with chronic total occlusion: critical appraisal of different state-of-the-art
Héctor M García-García1, Neville Kukreja, Joost Daemen
1Thoraxcenter, Erasmus Medical Center, Rotterdam, The Netherlands.
Insights
Treating chronic total occlusions (CTOs) requires multiple guidewires and devices, with a 60.6% success rate. Careful planning and adaptable techniques are crucial for managing complex CTO cases.
Area of Science:
- Cardiovascular Interventions
- Interventional Cardiology
- Vascular Biology
Background:
- Chronic total occlusions (CTOs) represent a significant challenge in interventional cardiology.
- Successful revascularization of CTOs can improve patient outcomes and quality of life.
Purpose of the Study:
- To describe the current strategies for treating CTOs at the Thoraxcenter.
- To critically evaluate the performance of advanced guidewires and devices in a prospective CTO registry.
Main Methods:
- A prospective registry of 165 CTOs in 160 consecutive patients over 20 months.
- Detailed documentation of guidewire/device usage, procedural techniques, and success rates.
- Evaluation of specific devices including CROSSER, Laser catheters, and SafeCross System.
Main Results:
- An overall success rate of 60.6% was achieved.
- A median of 4 guidewires (13 types) and 1 guiding catheter were used per case, with 74.5% requiring multiple guidewires/devices.
- Commonly used guidewires included PT Graphix intermediate, Miracle 3 g, and Crosswire NT. Over-the-wire balloons were the most frequent strategy (81.5%).
Conclusions:
- CTO treatment necessitates a high volume of guiding catheters and guidewires, alongside sophisticated devices.
- Thorough pre-procedural planning and flexible adaptation of techniques (e.g., parallel wire, see-saw) are essential.
- Prompt adjustments in approach are vital to mitigate complications associated with prolonged procedures.
Aims:
To describe the contemporary approach of chronic total occlusion (CTO) treatment of patients at the Thoraxcenter, Rotterdam, The Netherlands. Additionally, to make a critical appraisal of the performance of state-of-the-art CTO dedicated guidewires and devices in a prospective registry of patients.
Methods And Results:
During 20 months, a total of 160 consecutive patients (165 CTOs) were enrolled. The mean age was 61.5+/-11.1 years and 83.6% were male. In 91.5% of the patients this was the first attempt to open the CTO and 93.8% were de novo. The overall success rate was 60.6%. A median of 1 guiding catheter was used per case (Range: 1 to 9) and a median of 4 guidewires (Range: 1 to 11; 13 different types). 74.5% patients required more than one guidewire/device for the treatment of the CTO. The guidewires that most frequently crossed the CTO were the following: PT Graphix intermediate 33.0%, Miracle 3 g 27.4% and Crosswire NT 25.5%. The only device tested as a first option for the treatment of the CTOs was the CROSSER. Overall, the CROSSER system was used in 23 (13.9%) patients with a success rate of 60.9%. The Point 9(R) X-80 Laser catheter was used in 10 (6.1%) patients with a success rate of 60%. Another 3 patients were treated with the Point 7(R) laser catheter. Both were used either to facilitate the crossing of the balloon, or to treat primarily in-stent restenosis occlusions. The SafeCross(R) System was used in 15 (9.1%) patients and the success rate in these patients was 46.7%. The most common strategy used in this registry was the use of an over-the-wire balloon in 81.5% of the cases. The parallel wire technique was used in 27.3% of the cases and in 12.7% was converted into a "see-saw" technique. When a large false lumen was created, re-entry into the true lumen was attempted in 21.2% of the cases, by means of IVUS guided approach and/or the use of stiffer guidewires, such as a Confianza guidewire. Retrograde recanalisation was attempted in 10 cases (6.1%), in three cases a graft was used; the remaining cases were treated either via collaterals or the septal branches.
Conclusions:
The treatment of CTOs requires the use of a high number of guiding catheters and guidewires, as well as the use of sophisticated devices. The procedure must be carefully planned in advance as far as possible, as well as considering a prompt change in approach during the performance of the procedure to prevent complications derived from long procedures by using specific techniques such as parallel wire, see-saw, anchoring balloon, etc.
Related Concept Videos
Peripheral Artery Disease III: Interprofessional Care
Coronary Artery Disease V: Interprofessional Care
Atherosclerosis III: Management
Aneurysm III: Interprofessional Care
Angina IV: Management