Related Experiment Video
Updated: Jun 20, 2026

Functional and Physiological Methods of Evaluating Median Nerve Regeneration in the Rat
Published on: April 18, 2020
Finger thermoregulatory model assessing functional impairment in Raynaud's phenomenon
Alessandro Mariotti1, Giuliana Grossi, Paolo Amerio
1Department of Clinical Sciences and Bioimaging, "G. d'Annunzio" University, Chieti, Italy.
Abstract:
Raynaud's Phenomenon (RP) is a paroxysmal vasospastic disorder of small arteries, pre-capillary arteries, and cutaneous arteriovenous shunts of the extremities, typically induced by cold exposure and emotional stress. RP is either primary (PRP) or secondary to systemic sclerosis. In this study we use Control System Theory to model finger thermoregulatory processes in response to a standardized cold challenge (a diagnostic test routinely performed for differential diagnosis of RP). The proposed model is based on a homeostatic negative feedback loop, characterized by five distinct parameters which describe how the control mechanisms are activated and maintained. Thermal infrared imaging data from 14 systemic sclerosis subjects (SSc), 14 PRP, and 16 healthy control subjects (HCS) were processed. HCS presented the fastest active recovery, with the highest gain. PRP presented the slowest and weakest recovery, mostly due to passive heat exchange with the environment. SSc presented an intermediate behavior, with the longest delay of response onset. The estimated model parameters elucidated the level of functional impairment expressed in the various forms of this disease.
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Thermosensation
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Decreased Body Temperature
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...