Related Experiment Video
Updated: Jun 20, 2026

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Quantification of regional myocardial oxygen metabolism in normal pigs using positron emission tomography with
Takashi Temma1, Hidehiro Iida, Takuya Hayashi
1Department of Patho-Functional Bioanalysis, Graduate School of Pharmaceutical Sciences, Kyoto University, Kyoto, Japan.
Purpose:
Although (15)O-O(2) gas inhalation can provide a reliable and accurate myocardial metabolic rate for oxygen by PET, the spillover from gas volume in the lung distorts the images. Recently, we developed an injectable method in which blood takes up (15)O-O(2) from an artificial lung, and this made it possible to estimate oxygen metabolism without the inhalation protocol. In the present study, we evaluated the effectiveness of the injectable (15)O-O(2) system in porcine hearts.
Methods:
PET scans were performed after bolus injection and continuous infusion of injectable (15)O-O(2) via a shunt between the femoral artery and the vein in normal pigs. The injection method was compared to the inhalation method. The oxygen extraction fraction (OEF) in the lateral walls of the heart was calculated by a compartmental model in view of the spillover and partial volume effect.
Results:
A significant decrease of lung radioactivity in PET images was observed compared to the continuous inhalation of (15)O-O(2) gas. Furthermore, the injectable (15)O-O(2) system provides a measurement of OEF in lateral walls of the heart that is similar to the continuous-inhalation method (0.71 +/- 0.036 and 0.72 +/- 0.020 for the bolus-injection and continuous-infusion methods, respectively).
Conclusion:
These results indicate that injectable (15)O-O(2) has the potential to evaluate myocardial oxygen metabolism.
More Related Videos
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
15:10A Dual Tracer PET-MRI Protocol for the Quantitative Measure of Regional Brain Energy Substrates Uptake in the Rat
Published on: December 28, 2013
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...