Related Experiment Video
Updated: Jun 20, 2026

Extraction and Detection of Geosmin and 2-Methylisoborneol in Water and Fish using High-Capacity Sorptive Extraction Probes and GC-MS
Published on: July 3, 2025
Selective detection of diethylene glycol in toothpaste products using neutral desorption reactive extractive
Jianhua Ding1, Haiwei Gu, Shuiping Yang
1Department of Applied Chemistry, East China Institute of Technology, Fuzhou, Jiangxi Province 344000, PR China.
Abstract:
A rapid, sensitive method based on neutral desorption (ND) reactive extractive electrospray ionization mass spectrometry (EESI-MS) has been established for the selective quantitative detection of diethylene glycol (DEG) in toothpaste products without any sample pretreatment. The sensitivity and specificity of DEG detection were enhanced by implementing selective ion/molecule reactions in the EESI process, featuring the EESI mass spectra with the characteristic signals of DEG. The method provided a low limit of detection (LOD) (approximately 0.00002%, weight percent of DEG in toothpaste), reasonable recovery (97.6-102.4%), and acceptable relative standard deviations (RSD < 8%, n = 8) for direct measuring of DEG in the spiked toothpaste samples. Trace amounts of DEG in commercial toothpaste products have been quantitatively detected without any sample manipulation. The results demonstrate that nonvolatile compounds such as DEG can be sensitively liberated using the neutral gas beam for quantitative detection from the extremely viscous toothpaste containing solid nanoparticles, showing that ND-EESI-MS is a useful tool for the rapid characterization of highly complex and/or viscous samples at molecular levels.
More Related Videos
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Detectors-II
Masking and Demasking Agents
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on the metal...