Rapid Viscoelastic Characterization of Airway Mucus Using a Benchtop Rheometer
Published on: April 21, 2022
Interactions of airflow oscillation, tracheal inclination, and mucus elasticity significantly improve simulated cough
Anpalaki J Ragavan1, Cahit A Evrensel, Peter Krumpe
1Graduate Program in Biomedical Engineering, University of Nevada, Reno, NV 89557, USA.
Background:
Viscoelastic properties of simulated mucus, angle of tracheal inclination (theta), and high-frequency airflow oscillations on median displacement of simulated mucus during simulated cough were investigated in this study.
Methods:
Mucus simulants with viscoelastic properties similar to healthy individuals and patients with COPD were prepared using locust bean gum (LBG)-water solution (0.38 g LBG in 100 mL water) cross-linked with 3-mL and 12-mL borax-water solution (0.02 M), respectively. Aliquots of 0.3 mL of simulants were placed on a dry Plexiglas insert inside a D-shaped clear Plexiglas tracheal model. Movement of aliquots of mucus simulants was measured during cough of 0.3 s duration. Cough velocities studied (5-30 m/s) are typical of patients with weak expiratory muscles and airway obstruction. Studies were conducted with tracheal model placed horizontally (0 degrees) and at increasing theta (15 degrees, 30 degrees, and 45 degrees), with and without superimposed airflow oscillations during coughs. Effects of different parameters and their interactions on displacements of aliquots were compared using analysis of covariance (n = 849).
Results:
Significant positive nonlinear associations existed between displacement and cough velocity for both 3-mL and 12-mL simulants (P < .0001). Displacement was greatest for the cohesive 12-mL simulant at all cough velocities. Displacement increased significantly (P < .0001) as theta was increased for both types of simulants. Largest displacements at low cough velocities occurred with 12-mL simulant in the presence of oscillations at 45 degrees angle.
Conclusions:
Results support the use of airflow oscillations and sitting upright to facilitate mucus displacement during cough, particularly with thick, elastic mucus found in patients with COPD (P < .0001).
Related Concept Videos
Upper Respiratory Drugs: Antitussives, Expectorants, and Mucolytics
Antitussives include codeine, dextromethorphan (Robitussin), and benzonatate (Tessalon). Codeine and dextromethorphan exert their effects centrally by suppressing the cough reflex center in the medulla. Benzonatate operates peripherally within the respiratory tract by anesthetizing...
Chronic Obstructive Pulmonary Disease III: Chronic Bronchitis Features
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Trachea
Anatomical Features:
Location: About half of the trachea is situated in the neck, anterior to the esophagus, and extends from the larynx (at the level of the...
Drugs Used in Upper Respiratory Disorders: Overview
Antihistamines (e.g., Benadryl) block histamines from binding. Histamines are chemicals released during an allergic reaction in the body. As a...
The Bronchial Tree
The trachea, commonly known as the windpipe, is a tube that connects the larynx (voice box) to the bronchi. At a point called the carina, it bifurcates into two primary bronchi. The right primary bronchus is wider, shorter, and more vertical than the left primary...