Related Experiment Video
Updated: Jun 20, 2026

Digital Hybrid Model Preparation for Virtual Planning of Reconstructive Dentoalveolar Surgical Procedures
Published on: August 5, 2021
[Help for delineation: what kind of tools?]
Y Pointreau1, G Bera, I Barillot
1Clinique d'Oncologie Radiothérapie, Centre Henry-S-Kaplan, CHU Bretonneau, 37044 Tours cedex 9, France.
Radiotherapy planning has advanced with new techniques, but target volume delineation variations remain a challenge. This paper presents key recommendations to standardize these volumes for improved patient outcomes.
Area of Science:
- Medical Physics
- Radiation Oncology
Background:
- Recent advancements in radiotherapy techniques like conformational radiotherapy, intensity-modulated radiation therapy, and stereotactic radiation therapy necessitate precise target volume definition.
- International Commission on Radiation Units and Measurements (ICRU) reports 50 and 62 provide recommendations for target volume definition but lack specific guidelines for delineation.
- Intra- and interobserver variations in target volume delineation are significant sources of uncertainty impacting radiotherapy outcomes.
Purpose of the Study:
- To present the main recommendations for standardizing target volume delineation in radiotherapy planning.
- To address the critical issue of observer variability in defining clinical target volumes (CTVs) and planning target volumes (PTVs).
Main Methods:
- Review of existing guidelines and atlases for radiotherapy target volume delineation.
- Analysis of common practices and sources of variation in delineation processes.
- Synthesis of recommendations aimed at reducing interobserver variability.
Main Results:
- Identification of key areas contributing to delineation uncertainties.
- Presentation of a consolidated set of recommendations for consistent volume definition.
- Highlighting the importance of standardized protocols and training.
Conclusions:
- Standardized target volume delineation is crucial for reducing uncertainties in radiotherapy planning.
- Implementing the presented recommendations can help homogenize delineation practices across different institutions.
- Improved consistency in target volume definition is expected to enhance the precision and effectiveness of radiation therapy.
Related Concept Videos
Profile Leveling and Cross Sections
Leveling Equipment
Design Example: Marking Boundaries of a Site Using a Compass
Differential Leveling
Design Example: Maintaining Level of an Embankment
Taping Over Different Ground Profiles

