Related Experiment Video
Updated: Jun 20, 2026

A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
Calix[4]arene crown-4 ether modified glassy carbon electrode for electrochemical determination of norepinephrine
Hai-Li Zhang1, Ya Liu, Guo-Song Lai
1Department of Chemistry, Hubei Normal University, Huangshi 43500, PR China. hailizh@163.com
Abstract:
A sensitive and selective electrochemical method for the determination of norepinephrine (NE) was developed by using a calix[4]arene crown-4 ether (CACE) film modified glassy carbon electrode (GCE). The fabrication of the CACE film and its electrocatalytic effect for electrochemical oxidation of NE were investigated by electrochemical impedance spectroscopy (EIS) and voltammetric methods. It was found that the electrochemical behavior of NE on the CACE film modified electrode depended on the film thickness of CACE. Based on the electrochemical data, the CACE film surface coverage (theta), the charge transfer number (z) and the amount of the surface-bound NE (Gamma) were calculated. The effects of the experimental variables such as the solution pH and the applied potential were investigated for optimum analytical performance. Excellent linear relationships were obtained in two concentration ranges of NE: one was from 0.55 to 9.7 microM and the other was 9.7 to 230 microM. The detection limit (S/N = 3) of NE obtained by steady-state amperometry was 0.28 microM. The relative standard deviation (RSD) for 10 successive measurements of 0.05 mM NE was 2.2%. This method could be applied for the direct determination of NE in injection samples. In addition, effects of possible interferences (e.g. ascorbic acid, AA) were investigated. The present work provides an effective method for amperometric determination of NE by using a CACE modified electrode.
Related Concept Videos
Potentiometry: Membrane Electrodes
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Ion-Exchange Chromatography
Types of Reversible Electrodes
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential ensures...
Crown Ethers