Related Experiment Video
Updated: Jun 20, 2026

Screening of Axonal Degeneration in Carpal Tunnel Syndrome Using Ultrasonography and Nerve Conduction Studies
Published on: January 11, 2019
Histological validation of ultrasound-guided neurography in early nerve regeneration
Johan W van Neck1, B Stefan de Kool, J Ineke M Hekking-Weijma
1Department of Plastic and Reconstructive Surgery, Room Ee15.91, Erasmus MC, University Medical Center, P.O. Box 2040, Rotterdam 3000, The Netherlands. j.vanneck@erasmusmc.nl
Abstract:
Ultrasound-guided near-nerve neurography is a new tool that can be used to assess nerve regeneration before reinnervation occurs. In this study, ultrasound-guided near-nerve measurements were validated against axon diameter counts in rabbits during a 15-week regeneration period after a crush lesion of their peroneal nerve. The course of the nerve was determined ultrasonically, and the active near-nerve needle electrode was maneuvered just next to the nerve under ultrasound guidance. Measured action potentials were compared with axon diameter counts from histological sections of these same nerves. A moderate to good positive correlation was found, which reached a maximum of 0.7 at a cut-off of 3 microm, corresponding to the minimal size of the myelinated axons. Our results suggest that, following a similar validation study in humans, ultrasound-guided near-nerve neurography may be clinically useful when early evaluation of nerve activity is needed.