Stochastic resonance algorithm applied to quantitative analysis for weak chromatographic signals of alkyl halides and

Suyun Xiang1, Wei Wang, Jia Xia

  • 1State Key Laboratory of Materials-Oriented Chemical Engineering, College of Life Science and Pharmaceutical Engineering, Nanjing University of Technology, Nanjing, Jiangsu 210009, China.

Related Concept Videos

Mass Spectrometry: Alkyl Halide Fragmentation01:22

Mass Spectrometry: Alkyl Halide Fragmentation

Chlorine isotopes exist as 35Cl and 37Cl in a 3:1 ratio, while bromine isotopes exist as 79Br and 81Br in a 1:1 ratio. The mass spectrum of alkyl halides typically produces two distinct molecular ion peaks, the molecular ion peak, [M], and the molecular ion plus two, [M + 2] peak. The relative heights of these two peaks are proportional to the isotopic abundance ratios of the halide. For example, 2‐chloropropane and 1‐bromopropane display two peaks with relative peak heights in a 3:1 and 1:1...
High-Performance Liquid Chromatography: Types of Detectors01:15

High-Performance Liquid Chromatography: Types of Detectors

The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte properties and...
2D NMR: Heteronuclear Single-Quantum Correlation Spectroscopy (HSQC)01:19

2D NMR: Heteronuclear Single-Quantum Correlation Spectroscopy (HSQC)

Heteronuclear single-quantum correlation spectroscopy (HSQC) is a 2D NMR technique that reveals one-bond correlations between hydrogen and a heteronucleus. The HSQC experiment is similar to the heteronuclear correlation experiment (HETCOR) but is more sensitive. In the HSQC spectrum, the proton chemical shift is plotted on the horizontal F2 axis, while the 13C chemical shift is plotted on the vertical F1 axis. The corresponding proton and 13C spectra are also shown. The HSQC contour plot does...
Chromatographic Resolution01:15

Chromatographic Resolution

In chromatography, a solute moves through a chromatographic column and tends to spread, forming a Gaussian-shaped band. The longer the solute spends in the column, the broader the band becomes. The broadening can lead to overlaps within the column, affecting separation effectiveness.
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Chromatographic Methods: Terminology01:18

Chromatographic Methods: Terminology

Chromatography is an analytical technique widely used in fields such as chemistry, biology, environmental science, and pharmaceuticals to separate the components of a mixture and identify substances between them. The process of chromatography is based on the interactions between two distinct phases: the stationary phase and the mobile phase. The stationary phase is fixed in place by a supporting material, while the mobile phase moves over it, carrying the solutes. As the mobile phase travels,...
Mass Spectrometry: Complex Analysis01:21

Mass Spectrometry: Complex Analysis

Mass spectrometry is an important technique for the identification of pure compounds. However, it has some limitations for the analysis of complex mixtures, often due to excessive fragmentation making the spectrum too complicated to decipher. Mass spectrometry can be combined with suitable separation methods in sequence, forming hyphenated methods, which are useful in the analysis of complex mixtures.
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...