Purpose:
Bronchoscopy is an indispensable tool for invasive pulmonary evaluation with high diagnostic yield and low incidence of major complications. However, hypoxemia increases the risk of complications, in particular after bronchoalveolar lavage. Non-invasive positive pressure ventilation may prevent hypoxemia associated with bronchoalveolar lavage. The purpose of this study is to present a modified total face mask to aid bronchoscopy during non-invasive positive pressure ventilation.
Methods:
A commercially available full face mask was modified to allow introduction of the bronchoscope without interfering with the ventilator circuit. Bronchoscopy with bronchoalveolar lavage was performed in 12 hypoxemic non-ICU patients during non-invasive positive pressure ventilation in the ICU.
Results:
Patients had severely impaired oxygen uptake as indicated by PaO(2)/FiO(2) ratio 192 +/- 23 mmHg before bronchoscopy. Oxygenation improved after initiation of non-invasive positive pressure ventilation. In all patients the procedure could be completed without subsequent complications, although in one patient SpO(2) decreased until 86% during bronchoscopy. A microbiological diagnosis could be established in 8 of 12 patients with suspected for infection.
Conclusions:
Our modified face mask for non-invasive positive pressure ventilation is a valuable tool to aid diagnostic bronchoscopy in hypoxemic patients.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation I: Indication and Settings
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due to...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes: