Related Experiment Video
Updated: Jun 20, 2026

Two-Dimensional X-Ray Angiography to Examine Fine Vascular Structure Using a Silicone Rubber Injection Compound
Published on: January 7, 2019
Comparison between 64-row CT angiography and digital subtraction angiography in the study of lower extremities:
S Cernic1, F Pozzi Mucelli, A Pellegrin
1Unità Clinico Operativa di Radiologia, Università degli Studi di Trieste, Ospedale di Cattinara, Strada di Fiume 447, 34149, Trieste, Italy. stefanocernic@gmail.com
Purpose:
This study was undertaken to evaluate the potential of 64-row multislice computed tomography (CT) versus digital subtraction angiography (DSA) in detecting significant lesions of lower-extremity inflow and runoff arteries.
Materials And Methods:
Fifty-three patients underwent 64-row multislice CT and DSA over a mean of 36 days. The vascular tree was divided into 33 segments. Three readers independently reviewed the axial CT scans and multiplanar oblique and two- and three-dimensional reconstructions (maximum intensity projection and volume rendering) images to assess degree of stenosis according to four categories: 1 (0%-49% stenosis); 2 (50%-99% stenosis); 3 (occluded); 4 (not evaluable). In all cases, DSA was performed by arterial catheterisation.
Results:
In 53 patients, 1,440 segments were evaluated (infrarenal aorta and 16 arterial segments for each leg; 42 bilateral studies, 11 unilateral studies). Compared with DSA, CT angiography yielded 97.2% sensitivity, 97% specificity, 92.5% positive predictive value, 98.9% negative predictive value, 97.1% diagnostic accuracy and 95.4% concordance on the degree of stenosis.
Conclusions:
Sixty-four-row multislice CT proved to be helpful in detecting haemodynamically significant lesions in peripheral arterial occlusive disease and improved the results obtained with 4- and 16-slice multidetector CT. In addition, owing to the high spatial resolution and rigorous technique, no variations in the data obtained below the knee were detected, overcoming a limitation of earlier generations of CT scanners.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
04:35Sample Preparation for Computed Tomography-based Three-dimensional Visualization of Murine Hind-limb Vessels
Published on: October 7, 2021
Related Concept Videos
Imaging Studies VII: Vascular Imaging
Imaging Studies for Cardiovascular System V: CT
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...