Abstract:
Disposal petroleum pipes containing sludge and scale as a technically enhanced natural occurring radioactive material (TENORM) leads to internal and external radiation hazards and then a significant radiation dose to the workers. In order to contribute to a future waste management policy related to the presence of TENORM in the disposal sites of wasted petroleum pipes, scale and sludge as TENORM wastes are collected form these disposal pipes for radiometric analysis. These pipes are imported from onshore oilfields at south Sinai governorate, Egypt. The highest mean (226)Ra and (228)Ra concentrations of 519 and 50 kBq/kg respectively, were measured in scale samples. Sludge lies within the normal range of radium concentration. The average absorbed dose caused by the exposure to the wasted pipes equal to 4.09 microGy h(-1) from sludge and 262 microGy h(-1) from scale. This is much higher than the acceptable level of 0.059 microGy h(-1). Due to radon inhalation, important radon related parameters are calculated which advantage in internal dose calculation. Fairly good correlation between real radium content and radon exhalation rate for sludge samples is obtained. The hazards from sludge come from its high emanation power for radon which equal to 3.83%. The obtained results demonstrate the need of screening oil residues for their radionuclide content in order to decide about their final disposal.
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Nuclear Power
Nuclear Fuels
Nuclear fuel consists of a fissile isotope, such as uranium-235, which must be present in sufficient quantity to provide a...
Multiple Pipe Systems
Series Configuration
In a series configuration, fluid flows sequentially from one pipe...
Radiation Pressure: Problem Solving
The average value of the rate of momentum transfer divided by the absorbing area represents the average force per...
Nuclear Transmutation
Minor Losses in Pipes
Valves play a significant role in generating minor losses by obstructing or redirecting the fluid flow. When a valve is closed or partially closed, it restricts the flow...