X-ray third-harmonic generation in plasmas of alkalilike ions
Optics Letters
|September 29, 2009
Abstract:
We demonstrate theoretically the feasibility of x-ray near-resonant third-harmonic generation in a number of plasmas of Li- and Na-like ions as well as third-harmonic generation enhanced by phase matching using buffer plasmas.
Related Concept Videos
Electrophilic Addition to Alkynes: Halogenation
Introduction
Halogenation is another class of electrophilic addition reactions where a halogen molecule gets added across a π bond. In alkynes, the presence of two π bonds allows for the addition of two equivalents of halogens (bromine or chlorine). The addition of the first halogen molecule forms a trans-dihaloalkene as the major product and the cis isomer as the minor product. Subsequent addition of the second equivalent yields the tetrahalide.
Halogenation is another class of electrophilic addition reactions where a halogen molecule gets added across a π bond. In alkynes, the presence of two π bonds allows for the addition of two equivalents of halogens (bromine or chlorine). The addition of the first halogen molecule forms a trans-dihaloalkene as the major product and the cis isomer as the minor product. Subsequent addition of the second equivalent yields the tetrahalide.
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
Inductively coupled plasma (ICP) is the most widely used plasma source in atomic emission spectroscopy (AES), also known as Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). The ICP source, or torch, consists of three concentric quartz tubes with argon gas flowing through them. A spark from a Tesla coil initiates the ionization of argon, generating a high-temperature plasma.
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Atomic Emission Spectroscopy: Overview
Atomic emission spectroscopy (AES) is an analytical technique used to determine the elemental composition of a sample by analyzing the light emitted from excited atoms. In AES, atoms in a sample are excited to higher energy levels by thermal energy from high-temperature sources, such as plasma, arcs, or sparks. When these excited atoms return to lower energy states, they emit light at specific wavelengths characteristic of each element. The resulting atomic emission spectrum, which consists of...
Atomic Emission Spectroscopy: Lab
AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Mass Analyzers: Common Types
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...