Related Experiment Video
Updated: Jun 20, 2026

Heterotopic Auxiliary Rat Liver Transplantation With Flow-regulated Portal Vein Arterialization in Acute Hepatic Failure
Published on: September 13, 2014
Stent graft closure of a high flow splenorenal shunt after liver transplantation
Sergey Litvin1, Eli Atar, Michael Knizhnik
1Vascular and Interventional Radiology, Rabin Medical Center Petah Tikva, Israel. litvin_s@yahoo.com
Abstract:
We describe a patient after liver transplantation with a preexisting surgical splenorenal shunt close to the confluence of the splenic and superior mesenteric veins and a wide, short communication between the splenic and renal veins. To close the shunt, an inferior vena cava filter was inserted in the shunt and a vascular plug was placed in the splenic vein inside the filter. When this failed to stop the flow through the shunt, a covered stent was deployed at the superior mesenteric vein-portal vein junction.