Related Experiment Video
Updated: Jun 20, 2026

Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
Modified Ashworth scale reliability for measurement of lower extremity spasticity among patients with SCI
1Department of Medicine, University of Toronto, Toronto, Ontario, Canada. craven.cathy@torontorehab.on.ca
Study Design:
Observational study.
Objectives:
To report the intra-rater (one rater), inter-rater (two raters) and inter-session (one subject, sessions 1-5) reliability of lower extremity modified Ashworth scale (MAS) scores among patients with chronic spinal cord injury (SCI).
Setting:
Tertiary Academic Rehab Centre in Toronto, Canada.
Methods:
MAS scores of 20 subjects with chronic SCI (C5-T10 AIS A-D>12 months) were recorded for the hip abductors and adductors, knee flexors and extensors, and ankle plantar and dorsiflexors. MAS scores were assessed by two blinded raters (A and B) at the same time of day, weekly for 5 weeks using standardized test positions, a one-cycle per second metronome, with ratings recorded on the second cycle. MAS score reproducibility [intra-rater, inter-rater] were calculated using Cohen's Kappa. Intraclass correlation coefficients (ICCs) were calculated to determine inter-session (trials 1-5) reliability; Kappa values >or=0.81 and ICC values >or=0.75 were desired.
Results:
Intra-rater reliability was fair to almost perfect (0.2
Conclusions:
MAS was not reliable as an intra-rater tool for all raters, and showed poor inter-rater and modest inter-session reliability. MAS has inadequate reliability for determining lower extremity spasticity between raters (inter-rater) or over time (inter-session). It is recommended that the rehabilitation science community seek alternative measures for quantifying spasticity.