Related Experiment Video
Updated: Jun 20, 2026

Application of Biochip Microfluidic Technology to Detect Serum Allergen-specific Immunoglobulin E (sIgE)
Published on: April 21, 2019
Relationship between myopia and allergen-specific serum IgE levels in patients with allergic conjunctivitis
Tatsuya Mimura1, Satoru Yamagami, Tomohiko Usui
1Department of Ophthalmology, University of Tokyo Graduate School of Medicine, 7-3-1 Hongo, Bunkyo-ku, Tokyo, Japan. mimurat-tky@umin.ac.jp
Purpose:
Various exogenous allergens can cause allergic conjunctivitis, whereas refractive errors are also related (as an endogenous factor) to the pathogenesis of allergic conjunctivitis. However, little is known about the interaction between exogenous and endogenous factors in patients with allergic conjunctivitis. We investigated the relationship between refractive errors and exogenous allergens in patients with allergic conjunctivitis.
Methods:
Sixty patients with allergic conjunctivitis and 60 healthy subjects (non-allergy patients) were enrolled. Refraction was carried out in all subjects. In addition, total immunoglobulin E (IgE) and specific IgE levels for 12 inhaled allergens were measured by the capsulated hydrolic carrier polymer system.
Results:
The patients who were positive for-specific IgE to indoor allergens had higher myopia than those who were negative, including those positive for house dust IgE (-3.66 +/- 2.95 vs. -1.05 +/- 3.39, P = 0.0015), Dermatophagoides pteronyssinus (D. pteronyssinus) IgE (-3.50 +/- 2.91 vs. -1.01 +/- 3.46, P = 0.0021), and acarus IgE (-3.45 +/- 2.21 vs. -1.51 +/- 3.73, P = 0.0087), whereas antibody-positive and antibody-negative patients for outdoor allergens showed no significant differences of refraction. Refractions in indoor group (-3.58 +/- 3.42) and indoor/outdoor (-3.70 +/- 2.64) group were higher than those in outdoor group (-0.84 +/- 2.30, P = 0.0047 and P = 0.0032) and the non-allergy group (-1.30 +/- 1.48, P = 0.0082 and P = 0.0054) [-refraction] was significantly correlated with total IgE (r = 0.333, P = 0.0093), house dust (r = 0.355, P = 0.0054) and D. pteronyssinus (r = 0.379, P = 0.0028), while no correlation between refractive error and outdoor allergens was proven.
Conclusion:
These results suggest that specific IgE levels for indoor allergens, such as house dust, might be associated with refractive errors.
Related Concept Videos
Microbiome of the Eye
Allergic Reactions
Allergic Reactions: Anaphylaxis
Antibody Structure
Antibodies, also known as immunoglobulins (Ig), are essential players of the adaptive immune system. These antigen-binding proteins are produced by B cells and make up 20 percent of the total blood plasma by weight. In mammals, antibodies fall into five different classes, which each elicits a different biological response upon antigen binding.
The Y-Shaped Structure of Antibodies Consists of Four Polypeptide Chains
Antibodies consist of four polypeptide chains: two identical heavy...
Allergic Drug Reactions
Hypersensitivities
Types of Hypersensitivities
Hypersensitivity reactions are categorized into four types: Type 1, Type 2, Type 3, and Type 4. Each type has a distinct mechanism...

