Dosimetry for Cell Irradiation using Orthovoltage (40-300 kV) X-Ray Facilities
Published on: February 20, 2021
Development of improved free-air ionisation chamber as absolute dosimetry standard for low-energy X rays in INER
Chien-Hau Chu1, Wei-Peng Kuan, T Kurosawa
1Department of Biomedical Imaging and Radiological Sciences, National Yang Ming University, Taipei, Taiwan, ROC.
Abstract:
The National Radiation Standard Laboratory of the Institute of Nuclear Energy Research (INER) designed and constructed an improved Attix style free-air ionisation chamber (FAC) for low-energy X-ray measurements. Clinically, X rays in this energy range are used in mammography radiology. This chamber is also used to perform air-kerma measurements. The original Attix two-sectional design was redesigned by INER using the piston design. The correction factors were determined experimentally for volume estimation, ion recombination and air attenuation. The aperture transmission, wall transmission, electron loss and photon scatter correction factors were determined using Monte Carlo calculations. INER established the Bureau International des Poids et Mesures (BIPM) X-ray beam code and performed a comparison of secondary standard air-kerma calibration factors for 10-50 kV low- energy X rays to verify the experimental accuracy and measurement consistency of the improved chamber. The INER-NMIJ/National Institute of Advanced Industrial Science and Technology (AIST) experimental results comparison using a transfer chamber yielded a difference <1.0% at the 95% confidence level in calibration factors. The overall uncertainty for the X-ray measurement in terms of air kerma was <0.6% at the 95% confidence level. These results indicated that the improved FAC is capable of serving as a primary standard as well as a trace standard in low-energy X-ray calibration services in Taiwan and even forming a basis for the future mammography X-ray air-kerma primary standard.
More Related Videos
07:31Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Atomic Emission Spectroscopy: Instrumentation
Atomic Emission Spectroscopy: Lab
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.