Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography01:27

Imaging Studies III: Computed Tomography

DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
Imaging Studies for Cardiovascular System V: CT01:28

Imaging Studies for Cardiovascular System V: CT

Cardiac computed tomography (CT) scanning is an advanced cardiac imaging technique that utilizes CT technology, with or without intravenous (IV) contrast, to produce accurate cross-sectional virtual slices of specific areas of the heart, coronary circulation, and major blood vessels such as the aorta, pulmonary veins, and arteries. The computer processes these slices to generate three-dimensional images. Multidetector CT (MDCT) is a rapid form of CT scanning that captures multiple slices...
Imaging Studies II: Positron Emission Tomography and Scintigraphy01:25

Imaging Studies II: Positron Emission Tomography and Scintigraphy

Positron Emission Tomography (PET) is a medical imaging technique that provides crucial insights into the body's physiological functions at a molecular level. It is an indispensable resource for diagnosing, staging, and monitoring various illnesses, notably cancer, neurological disorders, and cardiovascular conditions.
Fundamental Principles of PET
Positron Emission Tomography01:29

Positron Emission Tomography

Positron emission tomography (PET) is a medical imaging technique involving radiopharmaceuticals — substances that emit short-lived radiation. Although the first PET scanner was introduced in 1961, it took 15 more years before radiopharmaceuticals were combined with the technique and revolutionized its potential.
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

RDI[Formula: see text]a regression detectability index for quality assurance in: x-ray imaging.

Physics in medicine and biology·2020
Same author

Can a channelized Hotelling observer assess image quality in acquired mammographic images of an anthropomorphic breast phantom including image processing?

Medical physics·2018
Same author

Evaluation of CT Angiography Image Quality Acquired with Single-Energy Metal Artifact Reduction (SEMAR) Algorithm in Patients After Complex Endovascular Aortic Repair.

Cardiovascular and interventional radiology·2017
Same author

Can the channelized Hotelling observer including aspects of the human visual system predict human observer performance in mammography?

Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)·2017
Same author

Can the non-pre-whitening model observer, including aspects of the human visual system, predict human observer performance in mammography?

Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)·2016
Same author

MULTICENTRE COMPARISON OF PATIENT AND DETECTOR DOSE FOR X-RAY-GUIDED EMBOLISATIONS OF ARTERIOVENOUS MALFORMATIONS IN THE BRAIN.

Radiation protection dosimetry·2016

Related Experiment Video

Updated: Jun 19, 2026

Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement
06:33

Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement

Published on: July 29, 2013

Development and validation of a low dose simulator for computed tomography.

R M S Joemai1, J Geleijns, W J H Veldkamp

  • 1Radiology Department, Leiden University Medical Centre, Leiden, The Netherlands. R.M.S.Joemai@lumc.nl

European Radiology
|October 1, 2009
PubMed
Summary

A new software simulator accurately mimics low-dose computed tomography (CT) image quality, enabling reliable observer studies on radiation exposure effects without needing actual low-dose scans.

More Related Videos

Using Micro-computed Tomography for the Assessment of Tumor Development and Follow-up of Response to Treatment in a Mouse Model of Lung Cancer
11:31

Using Micro-computed Tomography for the Assessment of Tumor Development and Follow-up of Response to Treatment in a Mouse Model of Lung Cancer

Published on: May 20, 2016

Related Experiment Videos

Last Updated: Jun 19, 2026

Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement
06:33

Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement

Published on: July 29, 2013

Using Micro-computed Tomography for the Assessment of Tumor Development and Follow-up of Response to Treatment in a Mouse Model of Lung Cancer
11:31

Using Micro-computed Tomography for the Assessment of Tumor Development and Follow-up of Response to Treatment in a Mouse Model of Lung Cancer

Published on: May 20, 2016

Area of Science:

  • Medical Imaging
  • Radiology
  • Image Processing

Background:

  • Observer studies are crucial for evaluating diagnostic image quality.
  • Assessing the impact of radiation dose on computed tomography (CT) image quality is essential for patient safety and diagnostic accuracy.
  • Simulating low-dose CT acquisitions can facilitate these studies.

Purpose of the Study:

  • To develop and validate software for observer studies.
  • To assess the effect of radiation exposure on diagnostic value in CT.
  • To create a reliable low-dose CT simulation tool.

Main Methods:

  • A low-dose simulator was developed by adding noise to raw CT data.
  • Validation involved acquiring images of cylindrical and anthropomorphic phantoms at varying dose levels (500 mA to 20 mA).
  • Simulated low-dose images were compared with actual low-dose acquisitions, including noise power spectrum (NPS) analysis.

Main Results:

  • The simulator produced image quality comparable to actual low-dose CT acquisitions.
  • Mean noise differences between simulated and actual images were 5.7% (cylindrical phantom) and 3.3% (anthropomorphic phantom).
  • Noise power spectra of simulated and actual images showed similar general shape and intensity.

Conclusions:

  • The developed low-dose simulator accurately represents image quality at lower radiation dose levels.
  • The software is suitable for use in clinical observer studies.