Design and experimental tests of a novel neutron spin analyzer for wide angle spin echo spectrometers

Peter Fouquet1, Bela Farago, Ken H Andersen

  • 1Institut Laue-Langevin, BP 156, F-38042 Grenoble Cedex 9, France.

Related Concept Videos

Nuclear Overhauser Enhancement (NOE)01:06

Nuclear Overhauser Enhancement (NOE)

Irradiation of a spin-active nucleus causes an increase or decrease in the signal intensity of neighboring nuclei that are not necessarily chemically bonded or involved in J-coupling. This phenomenon, called the nuclear Overhauser enhancement (NOE), results from through-space interactions between the nuclear spins. The NOE effect decreases with increasing internuclear distance and is generally not observed beyond 4 angstroms. In NOE, dipole-dipole interactions between neighboring spin-active...
Double Resonance Techniques: Overview01:12

Double Resonance Techniques: Overview

Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
Atomic Nuclei: Nuclear Spin01:08

Atomic Nuclei: Nuclear Spin

All atomic particles possess an intrinsic angular momentum, or 'spin'. Electrons, protons, and neutrons each have a spin value of ½, although protons and neutrons in nuclei may have higher half-integer spins owing to energetic factors.
Atomic nuclei have a net nuclear spin, , which can have an integer or half-integer value. In atomic nuclei, the spins of protons are paired against each other but not with neutrons, and vice versa. Consequently, an even number of protons does not contribute to...
NMR Spectrometers: Resolution and Error Correction01:14

NMR Spectrometers: Resolution and Error Correction

When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation01:26

Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation

Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy  (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Atomic Nuclei: Nuclear Spin State Overview01:03

Atomic Nuclei: Nuclear Spin State Overview

NMR-active nuclei have energy levels called 'spin states' that are associated with the orientations of their nuclear magnetic moments. In the absence of a magnetic field, the nuclear magnetic moments are randomly oriented, and the spin states are degenerate. When an external magnetic field is applied, the spin states have only 2 + 1 orientations available to them. A proton with = ½ has two available orientations. Similarly, for a quadrupolar nucleus with a nuclear spin value of one, the...