Related Experiment Video
Updated: Jun 19, 2026

Characterization and Application of Passive Samplers for Monitoring of Pesticides in Water
Published on: August 3, 2016
Modelling concentrations of decamethylcyclopentasiloxane in two UK rivers using LF2000-WQX
Oliver R Price1, Richard J Williams, Zhong Zhang
1Safety and Environmental Assurance Centre (SEAC), Unilever, Colworth Science Park, Sharnbrook, Bedfordshire MK44 1LQ, UK. oliver.price@unilever.com
Abstract:
Current regulatory environmental exposure assessments for decamethylcyclopentasiloxane (D(5)), used in a range of personal care products, are based on a number of erroneous assumptions. Using an estimated D(5) flux to waste water of 11.6 mg cap(-1) d(-1), a 95.2% removal rate in Sewage Treatment Plants (STP) and a dilution factor of 10 results in modelled surface water concentrations that are up to an order of magnitude higher than concentrations observed downstream of STPs in two UK rivers. A GIS-based water quality model (LF2000-WQX) was used to predict concentrations of D(5) in two UK rivers. Assuming the STP removal rate is reasonable, a waste water flux of 2.4 mg cap(-1) d(-1) is needed in order to obtain a reasonable match between predicted and observed in-river concentrations. This flux is consistent with measured effluent concentrations. The results highlight major uncertainties in estimating chemical emission rates for volatile chemicals used in personal care products and suggest that measured concentrations in waste water are needed to refine exposure assessments.