Terahertz Microfluidic Sensing Using a Parallel-plate Waveguide Sensor
Published on: August 30, 2012
Spot size transformer with a type-B antiresonant reflecting optical waveguide
Optics Letters
|October 3, 2009
Summary
A novel optical waveguide design precisely controls spot size without refractive index tuning. This antiresonant reflecting optical waveguide achieved low insertion loss and a high transformation ratio.
Area of Science:
- Optics and Photonics
- Materials Science
Background:
- Precise control of optical spot size is crucial for applications like optical interconnects and sensing.
- Traditional methods often rely on stringent refractive index control, limiting fabrication flexibility.
Purpose of the Study:
- To develop an optical waveguide that enables precise spot size control without requiring exact refractive index matching.
- To integrate a type-B antiresonant reflecting optical waveguide into a spot size transformer.
Main Methods:
- Incorporation of a type-B antiresonant reflecting optical waveguide structure.
- Optimization of the waveguide design for enhanced performance.
- Fabrication and characterization of the spot size transformer.
Main Results:
- Achieved precise control over the optical spot size.
- Obtained a low insertion loss of 0.9 dB.
- Demonstrated a large transformation ratio of 5.6.
Conclusions:
- The type-B antiresonant reflecting optical waveguide offers an effective solution for spot size transformation.
- The optimized design provides excellent optical performance with reduced fabrication constraints.
Related Concept Videos
Equivalent Circuits for Practical Transformers
The practical equivalent circuits of single-phase two-winding transformers exhibit significant deviations from their idealized versions due to the inherent properties of winding resistance and finite core permeability. These properties result in real and reactive power losses, affecting the transformer's performance. Understanding these deviations is crucial for designing more efficient transformers.
In a practical transformer, each winding exhibits resistance and leakage reactance. The winding...
In a practical transformer, each winding exhibits resistance and leakage reactance. The winding...
Transformers with Off-Nominal Turns Ratios
In scenarios involving parallel transformers with disparate ratings, developing per-unit models requires accommodating off-nominal turns ratios. This situation arises when the selected base voltages are not proportional to the transformer’s voltage ratings. Consider a transformer where the rated voltages are related by the term a. If the chosen voltage bases satisfy a relationship involving term b, term c is defined as the ratio of these bases. This ratio is then substituted into the rated...
Three-Winding Transformers
Three identical single-phase transformers can be configured to form a three-phase transformer connection, which involves high-voltage and low-voltage windings. The high-voltage windings are denoted by capital letters A-B-C, while the low-voltage windings are labeled with lowercase letters a-b-c, representing their respective phases. This notation helps distinguish between the high and low voltage sides of the transformer.
In the per-unit equivalent circuit of a grounded Y-Y three-phase...