The study of the pulse pressure wave using the technique of applanation tonometry is becoming more popular as a method of studying vascular stiffness. This review aims to present the uses, potential uses, strengths and weaknesses of the technique of applanation tonometry to assess augmentation index and pulse wave velocity. This article shall briefly discuss the practicalities of applanation tonometry, the physiological factors affecting pulse wave velocity and pulse wave analysis, the changes in pulse wave velocity and pulse wave analysis with pharmacological interventions, and the use of applanation tonometry as a prognostic tool. Although the technique of applanation tonometry seems initially promising, several pertinent issues need to be addressed before it can be used reliably as a clinical tool. Importantly, the technique of applanation tonometry to derive the central waveform from noninvasively-acquired peripheral data needs to be prospectively validated. As stated in this review, the transfer function has been extensively validated using invasive data, whilst noninvasive data estimation of the ascending aortic blood pressure is less accurate.
More Related Videos
06:04Pulse-Wave Velocity, Flow-Mediated Dilation, and Carotid Intima-Media Thickness to Assess Cardiovascular Risk in Population with Metabolic Syndrome
Published on: September 27, 2024
07:51Hydra, a Computer-Based Platform for Aiding Clinicians in Cardiovascular Analysis and Diagnosis
Published on: September 26, 2018
Related Concept Videos
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pre-Procedural Guidelines for Assessing Blood Pressure
Special considerations while measuring pulse
Assessment of the Cardiovascular System I: Subjective Data
Initial Enquiry
Ask the patient about their primary concern and thoroughly explore all reported symptoms.
Medical History
Investigate past illnesses affecting the cardiovascular system, such as angina, anemia, rheumatic fever, congenital heart disease, stroke, thrombophlebitis, dysrhythmias, varicosities
Inquire about symptoms...