Related Experiment Video
Updated: Jun 19, 2026

Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
Slow and discontinuous conduction conspire in Brugada syndrome: a right ventricular mapping and stimulation study
Pieter G Postema1, Pascal F H M van Dessel, Jacques M T de Bakker
1Cardiology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands.
Background:
Brugada syndrome (BrS) is associated with lethal arrhythmias, which are linked to specific ST-segment changes (type-1 BrS-ECG) and the right ventricle (RV). The pathophysiological basis of the arrhythmias and type-1 BrS-ECG is unresolved. We studied the electrophysiological characteristics of the RV endocardium in BrS.
Methods And Results:
RV endocardial electroanatomical mapping and stimulation studies were performed in controls (n=12) and BrS patients with a type-1 (BrS-1, n=10) or type-2 BrS-ECG (BrS-2, n=12) during the studies. BrS-1 patients had prominent impairment of RV endocardial impulse propagation when compared with controls, as represented by: (1) prolonged activation-duration during sinus rhythm (86+/-4 versus 65+/-3 ms), (2) increased electrogram fractionation (1.36+/-0.04 versus 1.15+/-0.01 deflections per electrogram), (3) longer electrogram duration (83+/-3 versus 63+/-2 ms), (4) activation delays on premature stimulation (longitudinal: 160+/-26 versus 86+/-9 ms; transversal: 112+/-5 versus 58+/-6 ms), and (5) abnormal transversal conduction velocity restitution (42+/-8 versus 18+/-2 ms increase in delay at shortest coupling intervals). Wider and more fractionated electrograms were also found in BrS-2 patients. Repolarization was not different between groups.
Conclusions:
BrS-1 and BrS-2 patients are characterized by wide and fractionated electrograms at the RV endocardium. BrS-1 patients display additional conduction slowing during sinus rhythm and premature stimulation along with abnormal transversal conduction velocity restitution. These patients may thus exhibit a substrate for slow and discontinuous conduction caused by abnormal active membrane processes and electric coupling. Our findings support the emerging notion that BrS is not solely attributable to abnormal electrophysiological properties but requires the conspiring effects of conduction slowing and tissue discontinuities.
More Related Videos
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
09:52Optocardiography and Electrophysiology Studies of Ex Vivo Langendorff-perfused Hearts
Published on: November 7, 2019
Related Concept Videos
Dysrhythmias IV: Characteristics of Bradyarrhythmias
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Electrophysiology of Normal Cardiac Rhythm
Acute Coronary Syndrome III: Diagnostic Studies