Related Experiment Video
Updated: Jun 19, 2026

Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
A cross-sectional study comparing variation in body surface area and chemotherapy dosing in pediatric oncology using
Wasil Jastaniah1, Mohammed Aseeri
1Princess Norah Oncology Center, King Abdul Aziz Medical City, Jeddah, Saudi Arabia.
Purpose:
Standardizing body surface area (BSA) determination is essential for avoiding variation in chemotherapy dosage calculations. In this study, we compared variation in BSA calculation using weight and height by the Mosteller formula with weight alone using recently adapted table at a local oncology center.
Methods:
Cross-sectional study of pediatric oncology patients presenting to a pediatric oncology clinic over a week period of time.
Results:
One-hundred consecutive pediatric oncology patients presented to the clinic. The mean BSA calculated by the Mosteller formula was 0.83 m(2) (SD 0.24) and the mean BSA determined by the table (based on weight alone) was 0.82 m(2) (SD 0.25). The mean variation in dosing between the two methods was 1.64% (SD 3.4). Only 13 out of 100 patients (13%) had equal dosing using both methods and 21 out of 100 patients (21%) had dosing variation greater than 5%. When comparing both methods, using paired t-test, the difference was statistically significant (t((99)) = 3.99 and p < 0.001).
Conclusion:
Significant differences in BSAbased chemotherapy dosing exist in our center. The Mosteller method should remain the standard until prospective studies are performed to determine the significance of this dosing variability on toxicity and survival outcome.
Related Concept Videos
Drug Dosing: Infants and Children
Comparing the Survival Analysis of Two or More Groups
Dose Size and Dosing Frequency: Determination Methods
Cancer Survival Analysis
Pharmacokinetics in Pediatric Patients: Drug Distribution
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses