Related Experiment Video
Updated: Jun 19, 2026

Use of Ultra-high Field MRI in Small Rodent Models of Polycystic Kidney Disease for In Vivo Phenotyping and Drug Monitoring
Published on: June 23, 2015
Comprehensive assessment of renal function and vessel morphology in potential living kidney donors: an MRI-based
Cristina Rossi1, Andreas Boss, Ferruh Artunc
1Section of Experimental Radiology, Department of Diagnostic and Interventional Radiology, Eberhard Karls University of Tübingen, Germany. cristina.rossi@med.uni-tuebingen.de
Objectives:
To test the feasibility of a single MR-based examination allowing for the comprehensive assessment of renal anatomy, function, and vascular status in candidates for kidney transplantation.
Materials And Methods:
Twelve healthy potential kidney donors (mean age: 47 +/- 14 [standard deviation] years, 3 men and 9 women) participated in the study, which was approved by the local ethics committee. MR-nephrography was performed using a navigator-gated T1-weighted saturation-recovery sequence (TrueFISP: TR/TE = 621.31 milliseconds/1.27 milliseconds, Flip angle = 70 degrees, TI = 300 milliseconds, BW = 977 Hz/Px, or TurboFLASH: TR/TE = 528 milliseconds/1.15 milliseconds, Flip angle = 8 degrees, TI = 300 milliseconds, BW = 600 Hz/Px). Images were acquired up to 60 minutes after the injection of 4 mL of gadobutrol. The glomerular filtration rate (GFR) was evaluated from the renal clearance of gadobutrol within the extra cellular fluid volume by exponential fitting of time-signal curves measured over the liver. MR-angiography was performed using a T1-weighted 3D-Flash sequence. The overall measuring time was 70 to 80 minutes. For each subject, GFR data were compared with the results of renal scintigraphy with Tc-labeled DTPA from the same day.
Results:
Kidney anatomy and vascular status were successfully assessed in all subjects. The results of MR-angiography were in excellent accordance with the surgical findings. MR-nephrography presented a good agreement to the scintigraphy (mean GFR from MR-nephrography = 117 +/- 24 mL/min per 1.73 m; mean GFR from scintigraphy = 116 +/- 26 mL/min per 1.73 m). The Bland-Altman-plot showed a mean difference in measurements pairs of -1 +/- 12 mL/min per 1.73 m. The absolute paired difference ranged between 0 and 22 mL/min per 1.73 m.
Conclusions:
The study showed the feasibility of the comprehensive assessment of renal anatomy, function, and vascular morphology, using 1 single MR examination. The proposed protocol may find immediate clinical application in the preoperative assessment of potential kidney donors.
Related Concept Videos
Kidney Transplant I: Introduction
Imaging Studies VII: Vascular Imaging
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies I: Kidney, Ureter, and Bladder Studies
Kidney Transplant II: Surgical Procedure