Two sides of a story. ACHE's Form 990 shows losses; group claims profit

Modern Healthcare
|October 8, 2009
PubMed
Abstract

No abstract available in PubMed .

Related Concept Videos

Minor Losses in Pipes01:25

Minor Losses in Pipes

In pipe systems, minor losses refer to energy losses arising from components such as valves, bends, fittings, expansions, and other features that disrupt the steady flow of fluid. These disturbances cause energy dissipation through turbulence and resistance, which engineers quantify to manage system efficiency effectively.
Valves play a significant role in generating minor losses by obstructing or redirecting the fluid flow. When a valve is closed or partially closed, it restricts the flow...
Formal Charges02:42

Formal Charges

In some cases, there are seemingly more than one valid Lewis structures for molecules and polyatomic ions. The concept of formal charges can be used to help predict the most appropriate Lewis structure when more than one reasonable structure exists.
Line Loss01:10

Line Loss

The different configurations of source-load connections include wye (star) and delta connections. The relationship between line and phase voltages and currents varies depending on the configuration. When the source is supplying power, it is transmitted through the wires to the load, and during this transmission, some power is absorbed by the wires, leading to line loss.
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
Reducing Line Loss01:18

Reducing Line Loss

In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Gain01:15

Gain

Gain and phase shift are properties of linear circuits that describe the effect a circuit has on a sinusoidal input voltage or current. The circuit's behavior that contains reactive elements will depend on the frequency of the input sinusoid. As a result, it is observed that the gain and phase shift will all be frequency functions.
Gain:
Suppose Vin is the input and Vout is the output signal to a circuit.
In- and Out-Groups01:31

In- and Out-Groups

People all belong to a gender, race, age, and social economic group. These groups provide a powerful source of our identity and self-esteem (Tajfel & Turner, 1979) and serve as our in-groups. An in-group is a group that we identify with or see ourselves as belonging to.