Aims:
The aim of the present study was to assess whether right ventricular (RV) contractility can be used for optimization of the interventricular (VV) interval and to study the acute hemodynamic effect of different VV intervals on right and left ventricular (LV) contractility in patients referred for cardiac resynchronization therapy (CRT).
Methods And Results:
Intracardiac LV and RV dP/dt were measured with a 0.014-in. sensor-tipped pressure guidewire during pacing at nine different VV intervals ranging from +80 ms (LV pre-excitation) to -80 ms (RV pre-excitation) in 26 patients who received a biventricular pacemaker. No correlation was found between the optimal VV intervals identified by maximum LV dP/dt and RV dP/dt, which were identical in only seven cases (27%). Only when testing slightly broader intervals (+/-20 ms) was there a statistically significant correlation (P= 0.037) between the optimized VV intervals. In the majority of patients (58%) either LV or RV pre-excitation was superior to simultaneous pacing according to LV dP/dt(max) measurements.
Conclusion:
RV dP/dt(max) failed to identify the optimal VV interval when compared with LV dP/dt(max) and can therefore not be recommended for VV optimization in CRT patients.
More Related Videos
10:17Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
Related Concept Videos
Electrophysiology of Normal Cardiac Rhythm
Cardiomyopathy V: Interprofessional Care
Pathophysiology of Cardiac Performance
Cardiomyopathy II: Dilated Cardiomyopathy
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Heart Failure Drugs: Inotropic Agents