Related Experiment Video
Updated: Jun 19, 2026

Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Assessing the blood volume and heart rate responses during haemodialysis in fluid overloaded patients using support
Faizan Javed1, Andrey V Savkin, Gregory S H Chan
1School of Electrical Engineering & Telecommunications, The University of New South Wales, Sydney, NSW 2052, Australia.
Abstract:
This study aims to assess the blood volume and heart rate (HR) responses during haemodialysis in fluid overloaded patients by a nonparametric nonlinear regression approach based on a support vector machine (SVM). Relative blood volume (RBV) and electrocardiogram (ECG) was recorded from 23 haemodynamically stable renal failure patients during regular haemodialysis. Modelling was performed on 18 fluid overloaded patients (fluid removal of >2 L). SVM-based regression was used to obtain the models of RBV change with time as well as the percentage change in HR with respect to RBV. Mean squared error (MSE) and goodness of fit (R(2)) were used for comparison among different kernel functions. The design parameters were estimated using a grid search approach and the selected models were validated by a k-fold cross-validation technique. For the model of HR versus RBV change, a radial basis function (RBF) kernel (MSE = 17.37 and R(2) = 0.932) gave the least MSE compared to linear (MSE = 25.97 and R(2) = 0.898) and polynomial (MSE = 18.18 and R(2)= 0.929). The MSE was significantly lower for training data set when using RBF kernel compared to other kernels (p < 0.01). The RBF kernel also provided a slightly better fit of RBV change with time (MSE = 1.12 and R(2) = 0.91) compared to a linear kernel (MSE = 1.46 and R(2) = 0.88). The modelled HR response was characterized by an initial drop and a subsequent rise during progressive reduction in RBV, which may be interpreted as the reflex response to a transition from central hypervolaemia to hypovolaemia. These modelled curves can be used as references to a controller that can be designed to regulate the haemodynamic variables to ensure the stability of patients undergoing haemodialysis.
More Related Videos
Related Concept Videos
Hemodialysis III: Nursing Management
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Hemodialysis II: Procedure and Complications
Heart Failure Drugs: Diuretics
Hemodialysis I: Introduction
Pre-Procedural Guidelines for Assessing Blood Pressure

