Related Experiment Video
Updated: Jun 19, 2026

Dosimetry for Cell Irradiation using Orthovoltage (40-300 kV) X-Ray Facilities
Published on: February 20, 2021
The impact of dosimetry uncertainties on dose-response analyses
1Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Room 7050, Bethesda, MD 20892, USA. gilberte@mail.nih.gov
Abstract:
Radiation dose estimates used in epidemiological studies are subject to many sources of uncertainty, and the error structure may be a complicated mixture of different types of error. Increasingly, efforts are being made to evaluate dosimetry uncertainties and to take account of them in statistical analyses. The impact of these uncertainties on dose-response analyses depends on the magnitude and type of error. Errors that are independent from subject to subject (random errors) reduce statistical power for detecting a dose-response relationship, increase uncertainties in estimated risk coefficients, and may lead to underestimation of risk coefficients. The specific effects of random errors depend on whether the errors are "classical" or "Berkson." Classical error can be thought of as error that arises from an imprecise measuring device, whereas Berkson error occurs when a single dose is used to represent a group of subjects (with varying true doses). Uncertainties in quantities that are common to some or all subjects are "shared" uncertainties. Such uncertainties increase the possibility of bias, and accounting for this possibility increases the length of confidence intervals. In studies that provide a direct evaluation of risk at low doses and dose rates, dosimetry errors are more likely to mask a true effect than to create a spurious one. In addition, classical errors and shared dosimetry uncertainties increase the potential for bias in estimated risks coefficients, but this potential may already be large due to the extreme vulnerability to confounding in studies involving very small relative risk.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
10:33Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification (ADCI) and Dose Estimation
Published on: September 4, 2017
Related Concept Videos
Dose-Response Relationship: Overview
Dose Response Curve: Conventional Versus Nonmonotonic
Biological Effects of Radiation
Dose-Response Relationship: Potency and Efficacy
Dose Size and Dosing Frequency: Determination Methods
Dose-Response Relationship: Selectivity and Specificity