Related Experiment Video
Updated: Jun 19, 2026

An Approach to Point-Of-Care Ultrasound Evaluation of the Abdominal Aorta
Published on: September 8, 2023
Azygos arch valves at computed tomography angiography and pitfalls related to its variety in appearance and function
Karin Steinke1, Arash Moghaddam
1Royal Brisbane and Women's Hospital, Herston, 4029 Queensland, Australia.
Insights
Azygos arch valves are common on computed tomography angiography (CTA) scans, with many showing signs of insufficiency. This study evaluated their prevalence and assessed insufficiency using high-rate contrast material injection during CTA.
Area of Science:
- Radiology
- Vascular Anatomy
Background:
- The azygos vein is a major venous channel in the thorax.
- Azygos arch valves are venous valves located at the junction of the azygos vein and the superior vena cava.
- Their prevalence and functional significance, particularly insufficiency, are not well-established in computed tomography angiography (CTA) imaging.
Purpose of the Study:
- To determine the prevalence of azygos arch valves.
- To evaluate the rate of azygos valve insufficiency.
- To assess these findings using chest or body computed tomography angiography (CTA) with high-rate contrast material injection.
Main Methods:
- Retrospective analysis of 321 CTAs performed with high intravenous injection rates (3-5 mL/second) of contrast material.
- Evaluation for contrast material reflux from the superior vena cava into the azygos vein.
- Identification of azygos valves and assessment of insufficiency based on contrast material presence posterior to the valve.
Main Results:
- Contrast reflux into the azygos vein was observed in 191 (59.5%) of 321 CTAs.
- Azygos valves were identified in 124 (64.9%) of these 191 examinations.
- Azygos valve insufficiency was present in 66 (53.2%) of the 124 examinations where valves were identified.
Conclusions:
- Azygos arch valves are frequently encountered during CTA.
- These valves exhibit considerable variation in size and shape.
- A significant proportion of identified azygos valves demonstrate features indicative of insufficiency.
Objective:
To evaluate the prevalence of azygos arch valves and assess azygos valve insufficiency at computed tomography angiography (CTA) of the chest or body with high rate contrast material injection.
Methods:
Three hundred twenty-one CTAs using high intravenous injection rates (3-5 mL/second) of 300 mgI/mL contrast material were retrospectively evaluated for the presence of contrast material reflux from the superior vena cava into the azygos vein. Among the patients with contrast material reflux, azygos valves were identified within the azygos arch. Age, sex, and site of contrast material injection were analyzed. Azygos valve insufficiency was considered to be present if there was contrast material within the azygos vein posterior to the azygos valve.
Results:
Of the 321 examinations, 191 (59.5%) showed reflux into the azygos vein. There was no significant difference in frequency of reflux into the azygos vein between right and left arm injection site (56.4% vs 63.5%, P = 0.20) or male and female patients (63.4% vs 55.0%, P = 0.12). No difference in mean age was noted between patients with reflux and those without it (P = 0.97). Azygos valves were identified in 124 (64.9%) of 191 CTA examinations with contrast reflux and pitfalls related to their appearance variety are discussed. No significant difference was found in valve frequency between male and female patients (66.0% vs 63.4%, P = 0.70). Contrast material posterior to the visible azygos valve was present in 66 (53.2%) of 124 examinations.
Conclusions:
Azygos arch valves are a common finding on CTA. They come in various sizes and shapes, and many of them show features of insufficiency.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Aneurysm II: Clinical Manifestations and Diagnostic Studies
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...