Related Experiment Video
Updated: Jun 19, 2026

Lateral-PLIF for Lumbar Spinal Arthrodesis: A Detailed Step-By-Step Surgical Technique
Published on: January 23, 2026
Results of lapidus arthrodesis and locked plating with early weight bearing
Matthew D Sorensen1, Christopher F Hyer, Gregory C Berlet
1Foot & Ankle Orthopedics, Woodbury, Minnesota.
Abstract:
In the endeavor toward Lapidus fusion, the authors have studied a new application of locked plating for the first tarsometatarsal joint. The goal was to assess the time to fusion, time to ambulation, rate of delayed union/nonunion, rate of revision, and need for hardware removal following the use of locked-plate technology in the fusion of the first tarsometatarsal joint. The findings denoted an average of 6.95 weeks to radiographic fusion, an average of 2 weeks to ambulation, a 9.52% rate of asymptomatic mal-union, a 0% rate of delayed union or nonunion, and a 0% rate of revision. The rate of need for hardware removal was 4.76%.