Related Experiment Video
Updated: Jun 19, 2026

Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
Femoral neck cut level affects positioning of modular short-stem implant
William M Mihalko1, Khaled J Saleh, Markus O Heller
1Campbell Clinic Orthopaedics, InMotion Orthopaedic Research Laboratory, University of Tennessee, Memphis, Tennessee 38017, USA.
Abstract:
A trend in total hip arthroplasty surgery has been to design more bone-preserving procedures, especially for younger patients. This study investigated the final implant positioning of a short metaphyseal femoral neck type of implant to determine whether leg length, caput collum diaphysis (CCD) angle, and offset could be re-created with different levels of femoral neck resection. Ten cadaveric hips in 6 whole-body specimens were used, with 3 fiducial markers to allow registration of computer navigation points to computed tomography scan data. Three femoral neck resection levels were investigated: 0 mm, +5 mm (the recommended level of resection), and +10 mm from the base of the femoral neck. Results showed that the CCD angle was significantly higher with 0-mm neck cut and the offset was lower, whereas the highest neck cut had longer leg-length results. Surgeons who use a short metaphyseal stem need to realize the importance of a proper femoral neck cut to restore anatomic parameters as well as the possible benefit of computer-assisted surgery to restore these anatomic parameters during surgery.